Configure RMON History Control Table Menu 
The History Control Table stores configuration records that define a users sample 
collection.  Collected samples can be viewed by using the arrow keys to select a 
particular record and pressing <CTRL> V. 
Figure 55: History Control Table 
My Switch               RMON History Control Table                  Admin Access   
 
Index Port Requested Buckets Granted Buckets Interval Owner 
1     5    70                70              4        Monitor 
33    3    30                30              3000     Monitor 
1200  5    20                20              2        Monitor 
 
 
<CTRL>  Z-Help S-Shell I-Insert L-Delete V-View 
Index 
The RMON History Control record index.  When creating a new record, enter an 
unused number in this field.  
Port 
The port to monitor. 
BucketsReq 
The number of buckets (1 to 4000) requested.  The default value is 50. 
BucketsGranted 
The number of buckets granted for this record.  This field is not editable. 
Interval 
The number of seconds (1 to 3600) between samples.  The default value is 1800. 
Owner 
A field describing the person who configured this record and any applicable 
contact information.  The RMON specification recommends that the string always 
start with the word “monitor”.
 