RuggedCom M2100 用户手册

下载
页码 30
19 
© 
2008 RuggedCom Inc. All rights reserved 
 
Rev106
 
4.5  Console Port Wiring 
 
A RS232 console port for configuration and management of the device is located on the LED 
display module shown in Figure 13.  This port is intended to be a temporary connection during 
initial configuration or troubleshooting and allows for direct access to the serial-based management 
console.  The connection is made using the DB9-Female to RJ45 console cable included in the 
device packaging shown in Figure 14.  Console connection settings are:  57600 baud, no parity 
bits, 8 data bits, and 1 stop bit. 
 
 
Figure 13:  Console port location on display board 
Figure 14:  M2000 Console cable 
 
For user reference, the console cable pin-out is show in Table 5. 
 
RuggedCom RS232 over RJ45 pin-out specification 
Signal Name (PC is DTE) 
DB9- Female 
RJ45 Male 
DCD – Carrier detect 
RxD – Receive data (to DTE) 
TxD – Transmit data (from DTE) 
DTR – Data terminal ready 
Signal GND 
DSR – Data set ready 
1* 
RTS – Ready to send 
CTS – Clear to send 
RI – Ring Indicator 
1* 
Table 4:  RS232 over RJ45 console cable pin-out 
 
After initial configuration, the RuggedSwitch device can be configured via a number of new 
mechanisms such as Telnet, and the built-in web server.  Consult the RuggedSwitch ROS User 
Guide for further details. 
 
NOTE: 
This port is not intended to be a permanent connection and the cable shall be less than 2m 
(6.5 ft) in length.