Connecting the server to the mains
4.4
Connecting the server to the mains
In its basic configuration level the server has a hot-plug power supply unit. A 
second hot plug power supply unit can be added to achieve redundant power 
supply. If a defect occurs in one power supply unit, the other power supply unit 
ensures continued operation of the server. 
V
CAUTION!
The installed power supply units automatically set themselves to a mains 
voltage in the range of 100 V - 127 V or 200 V -  240 V. Make sure that 
your local mains voltage is within the correct range.
Figure 10: Connecting the server to the mains
Ê
Connect the power cable with the insulated connector (1) to the power 
supply unit of the server, and plug the power plug (2) into a grounded outlet 
on the mains socket strip on the rack (see the technical manual for the rack).
I
A phase redundancy in the power supply of the server can be set up if 
two hot plug power supply units are installed. 
In this case, the two power supply units are connected to two different 
phases.