Fujitsu Siemens Computers BS2000/OSD 用户手册

下载
页码 111
U25339-J-Z126-1-7600
15
Controls and indicators
Control panel on the Business Server cabinet
4.1.2
Button functions
LCD BACK LIGHT
The LCD display STATUS (background) is illuminated for five minutes when you press
this button. The lights go out immediately when you press this button again.
POWER ON
When this button is pressed, the power supply of the entire system is switched on
sequentially. The order is predetermined. It begins with the Business Server system
components and ends with the peripheral devices connected to the PCI (Power Control
Interface). Then an IMPL is carried out. The system is ready for operation when the
display of P codes on the LCD display is extinguished.
If POWER ON IPL is configured, the operating systems is subsequently loaded (see
LOAD PRESET1-Frame on page 70).
POWER OFF
This is the button for switching off the power supply for the entire system. The sequence
begins with the peripheral devices connected to the PCI and ends with the Business
Server system components. The button is protected by a flap so that the system cannot
be switched off unintentionally.
CANCEL / ALARM STOP
When this button is pressed, the buzzer in the control panel is stopped and the CHECK
light is extinguished (same function as the
 key in SVP console window). If another
malfunction occurs after the light is extinguished, e.g. a machine error or a malfunction
in the power supply, the buzzer and the CHECK light are reactivated.
IMPL
When this button is pressed twice, the IMPL is executed and confirmed. The S130 is
initialized and the firmware is loaded in the individual components (CPU, IOP).
Furthermore, the IORSF selected in the IORSF Control Frame is activated. After the
IMPL is terminated, the P codes in the LCD display are extinguished. Afterwards an IPL
(Initial Program Load) of the BS2000 can be executed on the SKP.
If POWER ON IPL is configured, the operating system is loaded automatically (see
LOAD PRESET1-Frame on page 70).
This button loads another configuration or activates another IORSF.
The system will crash if an IMPL is executed during operation.
After you press the IMPL button for the first time the question
ARE YOU SURE?
is
displayed on the LCD display.
If no IMPL is to be executed, the CANCEL / ALARM STOP button must be
pressed.
If the IMPL is to be started, the IMPL button must be pressed a second time.
F3
!