Switching the SKP and S130 on and off using ATOP 3914
5.5 Switching the SKP and S130 on and off using ATOP 3914
The S130 can also be switched on automatically using the SKP in conjunction with the
ATOP 3914. The optional on/off facility is required for this. Furthermore, the S130 must be
configured to switch on and off automatically as part of the starting and shutting down
procedure for the SKP.
The ATOP switches the SKP on via its remote switching interface. The SKP switches the
S130 on. After the IMPL, the BS2000 system is started using the POWER ON IPL function
of the SVP or using the ATOP menu.
The BS2000 system can be operated both via the ATOP and manually by the operator.
To switch off the system, BS2000 must first of all be exited (ATOP/operator). The S130 is
switched off by the SKP when the SKP is switched off by the ATOP.
You will find information on operating and programming the ATOP in the ATOP operating
instructions enclosed.
V.24
On/off facility
LAN
Type-2 channel
SKP
LAN
ATOP
Console
SVP
S130