Standard processing in SVP mode
User frames
6.4.8.2
(AU2) AUXILIARY FRAME: IORSF CONTROL
Figure 28:  AUXILIARY FRAME: IORSF CONTROL screen
The IORSF files are displayed in this file. The file number of the current IORSF is displayed
in the
CURRENT NO. =
 field.
When you select a function and press the
 key, parameters are required in the other
input fields. Once you have entered the parameters and pressed the
 key, the
functions for the IORSF files are executed.
FUNCTION =>
The following functions are executed when the appropriate number is
entered:
1
SET NO
activates an IORSF. Entry of the set number in the
NEXT POWER ON RESET NO. =>
 field. An IMPL is then
2
PROTECT
engages/disengages IORSF protection from being
overwritten:
enter
P
 or
U
 before the appropriate number
3
SWAP
swaps two IORSFs: enter the numbers in the
SPECIFY SWAP NO
fields.
NEXT POWER ON RESET NO. =>
Enter the number of the IORSF file which is to be activated after the next
IMPL. You can only make an entry if you select function 1 beforehand.
              ----- AUXILIARY FRAME: IORSF CONTROL -----        E02L01F
        NO.    COMMENT
        0      S130TA1 // \UGENDATA.HW.S130.TA1.OSD.S130TA1 / 07.05.97
                          DATE 1997.04.30     TIME 16:00
        1      S130TA1X // \UGENDATA.HW.S130.TA1.OSD.S130TA1X / 07.05.97
                          DATE 1997.04.30     TIME 16:07
     P  2      S130TA1 // \UGENDATA.HW.S130.TA1.OSD.S130TA1 / 20.05.97
                          DATE 1997.05.14     TIME 15:20
     P  3      S130TA1X // \UGENDATA.HW.S130.TA1.OSD.S130TA1X / 20.05.97
                          DATE 1997.05.14     TIME 15:43
   FUNCTION=>                                               CURRENT NO. = 3
   *1 SET NO         NEXT POWER ON RESET NO. => 3
   *2 PROTECT        SPECIFY P(PROTECT) OR U(UNPROTECT)
   *3 SWAP           SPECIFY SWAP NO.            <=>
                                                              *PF8 NEXT PAGE
                CL-0       CPU-0 CHP-0        RUN
                                                           M
                                                   FLAG CODE = F6C0C100 00000F00
LTG                                                    TAST
ENTER
ENTER