Fujitsu 2000 SERIES 用户手册

下载
页码 285
CHAPTER 4 PCI Card Hot Maintenance in Red Hat Enterprise Linux 6 
4.6 Hot Replacement of PCI Express Cards 
88 
 
C122-E175-01EN 
 
To prevent a device name mismatch due to the failure, addition, removal, or replacement of an FC card, 
access the SAN disk unit by using the by-id name (/dev/disk/by-id/...) for the device name. 
If all the paths in a mounted disk become hidden when an FC card is hot replaced, unmount the disk. 
Then, execute PCI hot plug. 
FC card replacement procedure 
The procedure for replacing only a faulty FC card without replacing other peripherals is as follows. 
1.  Make the necessary preparations. 
Stop access to the faulty FC card, such as by stopping applications. 
2.  Confirm the slot number of the PCI Express slot. 
See ‘Confirming the slot number of a PCI Express slot’ in 
3.  Power off the PCI Express slot. 
See ‘Powering on and off PCI Express slots’ in 
4.  Physically replace the target card by using MMB Maintenance Wizard. This step is performed by the field 
engineer in charge of your system. 
For details on the operation of replacement, see step 1 to 7 of ‘Operation for Hot replacement of PCI 
Express card by Maintenance Wizard’ in 
5.  Reconfigure the peripheral according to its manual. 
For example, suppose that the storage device used is ETERNUS and that the host affinity function is 
used (to set the access right for each server). Their settings would need to be changed as a result of FC 
card replacement. 
6. 
Connect the FC card cable. 
7.  Power on the PCI Express slot. 
See ‘Powering on and off PCI Express slots’ in 
8.  Check whether there is an error in added FC card by MMB Maintenance Wizard. 
This step is performed by the field engineer in charge of your system. 
For details on the operation of replacement, see step 8 to 11 of ‘Operation for Hot replacement of PCI 
Express card by Maintenance Wizard’ in 
”. 
9.  Check the version of the firmware 
It is required that the firmware version of new FC card is same as that of the FC card which had been 
replaced. If the firmware version of new FC card is coincident with that of the FC card which had been 
replaced (current firmware version), it is not necessary to update the firmware version of new FC card to 
current firmware version. 
If the firmware version of new FC card is not coincident with that of the FC card which had been replaced 
(current firmware version), update the firmware version of new FC card to current firmware version. 
For how to update the firmware version, see Firmware update manual for fibre channel card. 
Note 
If you cannot confirm the firmware version of the FC card before replacing due to the fault of the FC card, 
check the firmware version of the FC card which is same type as the faulty one to update firmware 
version. 
10. Confirm the incorporation results. 
‘Confirming the FC card incorporation results’ 
describes the confirmation method. Start operation with the 
FC card again by restarting applications as needed or by other such means. 
11. Perform the necessary post-processing. 
If you stopped any other application in step 1, restart it too as needed. 
Confirming the FC card incorporation results 
Confirm the incorporation results of the FC card and the corresponding driver in the following method. Then, 
take appropriate action. Check the log. (The following example shows a log of FC card hot plugging.) 
As shown below, the output of an FC card incorporation message and device found message as the log 
output to /var/log/messages after the PCI Express slot containing the mounted FC card is enabled means that 
the FC card was successfully incorporated. 
scsi10:Emulex LPe1250-F8 8Gb PCIe Fibre Channel ¥ 
    Adapter on PCI bus 0f device 08 irq 59 ...(*1) 
    lpfc 0000:0d:00.0: 0:1303 Link Up Event x1 received ¥ 
    Data: x1 x0 x10 x0 x0 x0 0 ...(*2)