Fujitsu N800 用户手册
114
U41243-J-Z156-1-76
RemoteView storage medium
System expansions
8.7.3
Installing a memory module
Ê
Populate the module you have just removed with the additional DIMMs (see
the section “Installing DIMMs” on page 110).
the section “Installing DIMMs” on page 110).
If you are installing an additional module, this must be populated with the
DIMMs before installation.
DIMMs before installation.
I
Install the module with the component side down.
Ê
Open the insert/eject levers of the module (by rotating them outward 90°)
and slide the module into the slot guides of the empty slot until the levers
engage with the flanges in front of the guides.
and slide the module into the slot guides of the empty slot until the levers
engage with the flanges in front of the guides.
Ê
Simultaneously rotate the levers inward until they are flush with the edge of
the module.
the module.
Ê
Mount the memory module cover (four screws) and the front bezel).
Ê
Use
BIOS Setup
to configure the system and if necessary specify the correct,
expanded memory attributes.
8.8
RemoteView storage medium
For use
RemoteView
, the remote test and diagnosis system, on the N800 servers
an optional RemoteView IDE storage medium (chipDISK for RemoteView) is
available.
available.
The IDE storage medium is either pre-installed in the delivered server or is
included in the delivery unit as a separate component. This depends of the way
included in the delivery unit as a separate component. This depends of the way
RemoteView
has been ordered. The installation of the ChipDISK should only be
executed by service technicians.
Usually the IDE storage medium is shipped with the
RemoteView
/Diagnosis
System pre-installed.
I
A supplementary order of a ChipDISK do not contains the pre-installed
RemoteView
/Diagnosis System.