Configuration Possibilities
AXIS 5500 / AXIS 5550 User’s Manual
117
Read Back of
information
The AXIS 5500/AXIS 5550 supports bi-directional printing. The 
information from the printer is read back on the parallel port when the 
parameter Read Back Port (PRx_IN.) has the default setting of AUTO. 
However, it is required that the printer also supports bi-directional 
printing.
Please refer to your printer documentation for further details regarding 
bi-directional printing support.
Example:
Follow the instructions below to disable the bi-directional communication 
for logical printer PR1:
1. From the print server’s internal Web page, select 
Admin | Logical 
Printers.
2. Select the 
PR1 tab.
3. Set the 
Read Back Port parameter to NONE.
4. Click the 
OK button.
Debugging using the
Hex Dump Mode
When hex dump mode is enabled, the print data is printed as hexadecimal 
byte values rather than characters; printer control commands are also 
printed as hex values. This allows you to inspect what control and print 
characters are actually being sent to the printer, which is a useful 
debugging facility for more difficult printing problems.
Example:
Follow the instructions below to enable the hex dump mode for PR3:
1. From the print server’s internal Web page, select 
Admin | Logical 
Printers.
2. Select the 
PR3 tab.
3. Set the 
Hex Dump Mode Enabled radio button to YES.
4. Click 
OK.
Note:
The page length for hex dump printouts is determined by the lines per page value of the 