Elation Professional Pro FS 575 产品宣传页

下载
页码 2
Thank  you  for  purchasing  the  Pro  FS  575  by 
Elation Professional. For your convenience this 
follow spot has been fitted with its proper lamp 
and is ready to be used, there is no assembly 
required. Please read the following instructions 
before installing and using your new unit.
Operating Instructions:
The Pro FS 575 features a bright ZB-MSR575 
575 watt lamp, full focusing knob located on the 
top  as  well  as  zoom  control, control levers at 
the top of the unit for iris adjustment, and built-
in individual gel frames.  
Notice: When the unit is brand new, smoke 
will emit from the inside of unit. This is the 
paint on the inside burning off. There is no 
problem with the unit, this is normal.
To  replace  lamp;  
Unscrew  the  two  thumb 
screws  located  at  the  rear  of  the  unit,  slide 
out the lamp assembly, replace bulb and reas-
semble. Do not forget to unplug unit before 
replacing bulb!
The Breaker is located at the rear of the unit. 
For service, contact your Elation dealer.
Caution! Always disconnect from main power 
before  replacing  lamps  or  servicing  unit.  
Remember  to  always  replace  with  same  type 
of  lamp.
CAUTION! WARNING! The top of unit gets 
extremely hot, watch where you rest your 
hands, or objects that can melt or burn.
P
Ro
 
F
ollowSPoT 
Pro FS 
575
Discharge Lamp Warning:
 This fixture is fitted with a dis-
charge lamp which is highly susceptible to damage if improp-
erly  handled.  Never  touch  the  lamp  with  your  bare  fingers 
as  the  oil  from  your  hands  will  shorten  lamp  life.  Also,  never 
move the fixture until the lamps have had ample time to cool. 
Remember, lamps are not covered under warranty conditions.
This unit emits intense UV radiation which is harmful to the eyes 
and skin. The intense luminance of the lamp can cause severe 
damage to the retina. Never operate this unit without it’s covers, 
these covers have been specially designed to shield against UV 
radiation.
Epileptic Warning: Those suffering from epilepsy should avoid 
looking directly into the lamp at all times.
Avoid switching the fixture on and off repeatedly in short inter-
vals as this will reduce lamp life and intensity.
To achieve the intensity associated with discharge lamps, these 
lamps  use gas sealed in a high pressure environment to emit a 
brilliant output.  Due to the high pressure involved with the con-
struction of the lamp, the lamp may explode during prolonged 
extensive  use.  This  risk  is  increased  with  age,  added  care  is 
encouraged  when  dealing  with  older  lamps.  Extreme  caution 
should be used when operating this or any fixture fitted with a 
gas discharge lamp. Never open this unit while in use.