Use the chart below to determine the initial time values for INITIAL RINSE, CYCLE RINSE, INITIAL SOAP, and CYCLE SOAP based
on the desired concentration of the chemical being used. Check the concentration of the chemicals after running a few cycles and read-
just as necessary. 
CHEMICAL TIMER ADJUSTMENTS CONTINUED
4
JPX-160
Chemical Ratio         Chemical                Chemical          Initial                Cycle                 Initial                 
Cycle  
(parts water to
Concentration        Concentration      Rinse
Rinse
Detergent
Detergent
one part chemical) (percent in water)      (ounces per        
(sec)
(sec)
(sec)
(sec)
10 gallons water)
5000
0.02%
0.3
7
4
3
1
3000
0.03%
0.4
12
7
5
1
2500
0.04%
0.5
14
8
6
2
2000
0.05%
0.6
18
10
8
2
1500
0.07%
0.9
24
14
10
3
1000
0.10%
1.3
36
20
16
4
800
0.13%
1.6
45
26
20
5
600
0.17%
2.1
60
34
26
6
400
0.25%
3.2
90
51
39
9
300
0.33%
4.3
119
68
52
13
250
0.40%
5.1
143
82
63
15
200
0.50%
6.4
179
102
78
19
I
N
S
T
R
U
C
T
I
O
N
S
JPX-200
Chemical Ratio         Chemical                Chemical          Initial                Cycle                 Initial                 
Cycle  
(parts water to
Concentration        Concentration      Rinse
Rinse
Detergent
Detergent
one part chemical) (percent in water)      (ounces per        
(sec)
(sec)
(sec)
(sec)
10 gallons water)
5000
0.02%
0.3
11
5
8
1
3000
0.03%
0.4
18
9
14
2
2500
0.04%
0.5
22
10
16
2
2000
0.05%
0.6
27
13
21
2
1500
0.07%
0.9
36
17
27
3
1000
0.10%
1.3
54
26
41
5
800
0.13%
1.6
67
32
52
6
600
0.17%
2.1
90
43
69
8
400
0.25%
3.2
134
64
103
12
300
0.33%
4.3
179
85
137
16
250
0.40%
5.1
215
102
165
19
200
0.50%
6.4
269
128
206
24