Smeg JGFC34SKB 用户手册

下载
页码 32
  
Instruction for the installer 
 
10
 
 
 
3.2  Burner and nozzle characteristics table (60 cm. models) 
 
 
 
 
 
 
Burner 
 
Rated 
heating 
capacity 
(kW) 
 
LPG – G30/G31
  
28/37 mbar
 
 
 
 
 
Nozzle 
diameter 
1/100 mm 
By-pass 
mm 
1/100 
Reduced  
flowrate 
(W) 
Flowrate  
g/h G30 
 
Flowrate  
g/h G31 
 
 
 
Auxiliary 
 
1.0 
50 
30 
350 
73 
 
71 
 
 
 
Semi-rapid 
 
1.75 
65 
33 
450 
127 
 
125 
 
 
 
Rapid (3) 
 
3.0 
85 
45 
800 
218 
 
214 
 
 
 
Rapid (5) 
 
2.3 
75 
45 
800 
167 
 
164 
 
 
 
Triple crown 
 
3.2 
91 
65 
1500 
233 
 
229 
 
 
 
Oven 
 
3.2 
87 
48 
850 
233 
 
229 
 
 
 
 
 
 
Grill 
 
3.0 
87 
// 
// 
218 
 
214 
 
 
 
   
Burner 
 
Rated 
heating 
capacity 
(kW) 
 
NATURAL GAS – G20
  
20 mbar
 
 
 
 
 
Nozzle diameter 
1/100 mm 
Reduced Flowrate 
(W) 
 
 
 
Auxiliary 
 
1.0 
72 
350 
 
 
 
Semi-rapid 
 
1.75 
97 
450 
 
 
 
Rapid (3) 
 
3.0 
115 
800 
 
 
 
Rapid (5) 
 
2.3 
103 
800 
 
 
 
Triple crown 
 
3.5 
133 
1500 
 
 
 
Oven 
 
3.2 
130 
850 
 
 
 
Grill 
 
3.0 
130 
//