Instructions for the Installer
 
 
 
31 
5.5  Reassembling the hob skin 
Reverse the procedure described in point “5.1 Removing the hob skin”. 
 
 
 
When replacing the cover plates, check that the seals are fitted correctly. 
 
 
Fit the pan stands as described in point 
 
5.6  Adjusting the minimum setting for natural ga 
Reassemble the components on the burner and fit the 
knobs onto the tap rods. 
 
Light the burner and turn it to the minimum 
 setting. 
Remove the knob again and adjust the regulator 
screw inside or beside the tap rod (depending on the 
model) until an even minimum flame is obtained. 
Put the knob back in place and check the stability of 
the burner flame (the flame must not go out when the 
knob is turned quickly from the maximum to the 
minimum setting). 
 
5.7  Adjusting the minimum for bottled gas 
To adjust the minimum level when using bottled gas, the adjuster screw inside or 
beside the tap rod must be turned fully clockwise (depending on the models). 
The diameters of the bypasses for each individual burner are stated in point “5.2 
Adjusting for bottled gas". 
 
 
 
After adjusting for use of a gas other than the gas used for testing the appliance, 
replace the label on the casing with the label for the new gas. The label is supplied in 
the bag with the LPG nozzles (G30 - G31).
 
 
5.8  Hob burner layout 
 
 
Burner type 
 
1 Auxiliary 
2 Semi rapid 
3 Rapid 
4 Ultra rapid 
 
 
 
 
5.9  Greasing the gas taps 
 
 
Over time, the gas taps may become stiff or jam. Clean their insides and change their 
lubricating grease. This operation must be carried out by a skilled technician.