Smeg A42-5 用户手册

下载
页码 28
 
 
Instructions for the installer
 
 
40 
4.  FINAL OPERATIONS 
 
After replacing the nozzles, reposition the flame-spreader crowns, the 
burner caps and the grids. 
 
 
 
Following adjustment to a gas other than the preset one, replace the gas 
adjustment label fixed to the appliance with the one corresponding to the 
new gas. This label is in the packet together with the nozzles. 
 
 
 
4.1 Adjustment of minimum for natural gas 
Light the burner and turn it to the minimum 
position 
. Extract the gas tap knob and turn the 
adjustment screw at the side of the tap rod until 
the correct minimum flame is achieved.  
Replace the knob and check burner flame 
stability: (rapidly turning the knob from maximum 
to minimum position, the flame should not go 
out). Repeat the operation on all the gas taps. 
 
4.2 Regulation of minimum for LPG 
For regulating the minimum with LPG, the screw at the side of the tap rod 
must be turned clockwise all the way. 
The bypass diameters for each individual burner are shown in paragraph 
“3.2  Burner and nozzle characteristics table”. When adjustment is 
complete, re-seal the by-passes using wax or an equivalent material. 
 
4.3 Positioning and levelling of the appliance 
 
Having carried out the electricity and gas hook-up, level the appliance 
using the four adjustable legs.