KitchenAid 5KSB555AOB 用户手册

下载
页码 18
BLENDER SERVICE MANUAL
7
Blender Service Procedures
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical 
shock.
Unplug blender or disconnect power before servicing.
Before starting any service procedure, review the 
“Safety Guidelines” in the front of this manual.
Perform any blender disassembly on a clean surface 
and provide a cushion for the power base to avoid 
scratching the surface of the product.
Power Base Access (Fig. 9)
To access the power base (1), remove four rubber feet 
(2) on the bottom of the power base (1). Remove four 
Phillips head screws (3) with a clean, medium-sized 
Phillips screwdriver.
Figure 9
If any of the rubber feet (2) are heavily soiled or 
cracked, you should replace all four of them.
When replacing or installing the rubber feet (2), make 
sure that they are all inserted equally into the power 
base (1) so that the blender will sit level on the work 
surface.
Power Cord Replacement (Fig. 10)
Always be sure to inspect the condition of the blender’s 
power cord (4) before running the unit.
Replace the power cord (4) when heavily soiled, cut, or 
damaged in any way.
Once the four screws (3) on the bottom of the power 
base (1) are removed, the upper housing (5) and
base (6) can be easily separated for power cord (4) and 
component inspection.
Note the orientation of the power cord so that the 
proper orientation can be repeated when installing the 
new cord assembly.
To replace the power cord (4), disconnect filter 
connector (7) and remove ground screw (8) with a 
Phillips screwdriver.
Remove the original power cord (4) by sliding the 
power cord strain relief from the upper housing (5).
Figure 10
Before installing the new power cord (4), remove any 
soil from the base (6) using a mild dishwashing soap.
If the base (6) is contaminated or stained, replace the 
base (6).