Weigh Hopper Installation 
Remove the weigh hopper from the shipping box and install it in the blender on the load cell 
brackets.  Connect the airline and close the mixer door, securing the latch. 
Figure 25: Weigh Hopper 
 
Note:   THE WEIGH HOPPER ASSEMBLY MUST HANG FREELY AND BE 
FREE FROM FRICTION, WITH NO MECHANICAL 
OBSTRUCTIONS OTHER THAN THE LOAD CELL ITSELF. 
Final Connections 
Connect the blender to the appropriate power source. 
Connect the compressed air piping, ensuring that a 5-micron air filter is installed, along with 
the proper water trap, and lubrication unit, if required. Verify that 60 psi (4.14 bar) of clean, 
dry compressed air is supplied to the blender. 
Note:   Again, make sure that proper air supply connections are made to the 
blender, as dirty, contaminated, wet air can damage blender components 
eand can quickly cause poor performance and accuracy! 
Note:   Make sure that the blender is supplied with clean, dry,  
60 psi (4.14 bar) compressed air. 
After powering up the blender the following screen will be shown: 
Figure 26: Display Startup Screen 
 
 
Note:   It may take 45-50 seconds for the screen to appear. 
BF1-615.3 
Chapter 3: 2BInstallation 