Bunn 41170.0001A 用户手册

下载
页码 9
Page 9
200˚         CAL --> 
200˚
(-)         BrewTank        (+)
Insert an accurate thermometer approximately 7-8˝ into tank. Adjust the number 
on the right with +/- until it matches reading of thermometer. Press the hidden 
program button.
41170.1 050312
PROGRAM FUNCTIONS
FACTORY DEFAULTS
NO                      YES
AutoPOD BREWER
VERSION     xx.xx
FACTORY DEFAULTS
Reset all brew settings, calibrations back to factory presets.
Requires following "INITIAL SETUP" procedure.
EXIT PROGRAM MODE TO MAIN SCREEN
Model:
Software version:
       #        REFILL       ###
(-)            DONE           (+)
REFILL Adjust sensitivity of refill probe according to water quality. Always 
make sure that the # on the right is larger than the # on the left when 
water is contacting the tank refill probe.
SET REFILL
   NO       THRESHLD   YES
SET REFILL
Press "YES" to access the refill screen. FOR TRAINED TECHNICIANS ONLY. 
IMPROPER SETTINGS CAN RESULT IN OVER FLOW!
ReducedPowerLevel
(-)               30             (+)
# BrewsSealWarng
(-)              9950            (+)
REDUCED POWER LEVEL
Reduce power/number only when thin/loose pods cause brewing issues.
BREW SEAL WARNING
Sets the count number for "REPLACE SEAL" message.
WATER PUMP POWER
(-)              100            (+)
FACTORY USE ONLY
DO NOT ADJUST
CAL TEMPERATURE
   NO       SENSORS?   YES
CALIBRATE TEMPERATURE PROBE
Press "YES" to access the calibration screen.
LEVEL 3
2nd THERM FAULT
DISABLE ENABLE
FACTORY USE ONLY
DO NOT ADJUST