 SERVICING INSTRUCTIONS (continued) 
23 
IMPORTANT:  Water pressure 
must be between 20 p.s.i and 
90 p.s.i. flowing pressure.         
If water pressure exceeds this 
value, or if water pressure     
varies greatly, a pressure   
regulator must be installed in 
the water supply line. 
 
 
 
 
 
IMPORTANT:  
Before setting 
assembly into tank, make sure 
tank lid gasket is properly 
seated on flange of lid.           
DO NOT OVER-TIGHTEN.  
 
 
 
 
 
 
 
 
 
 
 
 
IMPORTANT:  When mounting 
thermostat, be sure a new seal 
washer is placed below the    
fitting on the capillary line. 
Push sensing bulb thru tank lid 
until fitting seats. 
Tighten capillary lock nut only 
enough to ensure no water  
leakage.  Excessive tightening 
is not necessary.  
 
 
IMPORTANT:  When replacing 
heating element, also replace 
seal gaskets. 
 
 
 
 
 
TIMER ADJUSTMENT  
 
The amount of water dispensed automatically during a brew cycle 
is controlled by the timer. 
 
Place empty decanter under brew chamber.  Press BREW       
button.  Brewer should dispense one decanter of water.  To     
adjust amount: 
 
Remove brew chamber and button plug.  Adjust knob on timer;  
clockwise increases time.  Run several cycles to check amount of 
water delivered.  Replace button plug. 
 
REMOVE TANK LID ASSEMBLY 
 
Unplug brewer or turn circuit breaker OFF.  Turn OFF water   
supply.  Remove top panel.  Pull vent tube and inlet elbow out of 
basin pan. 
 
Pull water inlet tube out of basin pan.  Remove basin pan. 
 
On models with faucet, disconnect inlet pipe at faucet shut-off 
valve and outlet pipe at faucet. 
 
Disconnect all wiring from thermostat, hi-limit, and heating       
element. 
 
Loosen center screw on tank hold-down bracket.  Remove    
hold-down bracket by sliding short slotted end off of locking stud 
and lifting it off.  Remove cover assembly by lifting it straight up. 
 
Reassemble in reverse order. 
              
REPLACE THERMOSTAT 
 
Unplug brewer or turn circuit breaker OFF.  Turn OFF water   
supply.  Remove top panel. 
 
Disconnect all wiring from thermostat only.  Loosen and free jam 
nut from pass-thru fitting securing temperature sensing bulb.   
Remove two screws holding thermostat to bracket. 
 
Lift out thermostat, sensing bulb and thermostat gasket. 
 
Reassemble in reverse order. 
 
REPLACE HEATING ELEMENT 
 
Remove tank lid assembly per above. 
 
Remove two hex nuts holding element to cover.  Pull element 
from mounting holes. 
 
Reassemble in reverse order.