INSTALLATION (continued) 
NOTE:  This equipment must be 
installed to comply with          
applicable federal, state and  
local plumbing codes and       
ordinances. 
 
 
WARNING: 
SHOCK HAZARD 
 
Brewer must be properly 
grounded to prevent possible 
shock hazard.  DO NOT        
assume a plumbing line will  
provide such a ground.        
Electrical shock will cause death 
or serious injury. 
 
IMPORTANT: 
Supply power must match 
nameplate for voltage and 
phase.  Connecting to the 
wrong voltage will damage the 
brewer or result in decreased 
performance.  Such damage is 
not covered by warranty. 
 
 
IMPORTANT: 
The ground prong of the plug is 
part of a system designed to 
protect you from electrical shock 
in the event of internal damage.  
Never cut off the ground prong 
nor twist a blade to fit an         
existing receptacle.  Contact a      
licensed electrician to install the 
proper circuit and receptacle. 
NSF requires that the brewer be able to be moved for cleaning 
underneath.  A flex line or loops of copper tubing will satisfy this 
requirement. See Figure 2 below. 
 
 
 
 
 
 
 
 
 
 
 
 
In some areas, local codes require a backflow preventer  (check 
valve)  to be installed on the inlet water line.  If a backflow        
preventer is used, you must install a water hammer arrester in 
the incoming line, between the backflow preventer and the 
brewer inlet, as far away from the brewer as space will allow.  
This will relieve the excessive back  pressures that can cause 
faucet leaks and solenoid malfunctions.  
 
IMPORTANT: 
Tank must be full of water before connecting brewer to electrical 
power.  Heating elements will be damaged if allowed to  operate 
without being fully submerged in water.  Damage caused by    
operating the brewer without water in the tank is NOT COVERED 
BY WARRANTY

 
ELECTRICIAN’S INSTALLATION INSTRUCTIONS 
 
REFER TO ELECTRICAL SPECIFICATIONS  provided in the 
Owner's Manual, specification sheet, and on the nameplate. 
 
Some models are equipped with a cord and plug.  They require: 
1.    A  circuit that meets or exceeds the electrical requirements         
2.    A properly installed and grounded receptacle configured   
       to match the brewer plug. 
 
Some models are designed to be connected directly to the     
electrical circuit.  They require: 
1.
A circuit that meets or exceeds the electrical requirements 
2.
Conduit and fittings that meet applicable electrical codes. 
3.    The ground lug of the brewer must be connected to a suitable 
       electrical ground. 
Water Supply Installation 
NEMA 5-15R
RECEPTACLE
NEMA 5-15P
PLUG
GROUND
PIN
Typical Plug/Receptacle  
Configuration