Stanley Black & Decker GT18B02 用户手册

下载
页码 27
10 ► GT18B01-B02 User Manual
OPERATION
PREPARATION FOR USE
Do not operate the power unit until you have read the 
engine operating and maintenance instructions manual 
furnished with the unit.
1. ENGINE CRANKCASE OIL LEVEL  
   
Always check the oil level before starting the engine. Make 
sure the oil level is at the FULL MARK on the dipstick. Do 
not overfill. Use detergent oil classified "For Service SE, 
SF, SG" as specified in the engine operating and mainte-
nance manual. See engine manual for oil viscosity grade.
2. SPARK PLUG
On power units equipped with Briggs & Stratton Engines, 
ONLY Champion RC12YC or equivalent can be used.
Incorrect type spark plugs can produce radio frequency 
interference that will corrupt and damage the controller. 
Failure to use the correct spark plug could result in a war-
ranty that will not be considered.
3. ENGINE FUEL LEVEL
 
Check the fuel level. If low, fill with un-leaded gasoline with 
a minimum of 85 octane. 
          
            
4. HYDRAULIC FLUID  
Check the dip stick in the hydraulic fluid reservoir for the 
proper fiuid level. Use fluids meeting the following specifi-
cations.
Viscosity (Fluid Thickness)
U.S. 
   METRIC
50°F 450 SSU Maximum 
10°C 95 C.S.
100°F 130-200 SSU 
 
38°C 27-42 C.S.
140°F 85 SSU Minimum  
60°C 16.5 C.S. Min
Pour Point -10°F/-23°C Minimum (for cold startup)
Viscosity Index  (ASTM D-2220) 140 Minimum
Demulsibility  (ASTM D-1401) 30 Minutes Maximum
Flash Point  (ASTM D-92) 340°F/171°C Minimum
Rust Inhibition  (ASTM D-665 A & B) Pass
Oxidation  (ASTM D-943) 1000 Hours Minimum
Pump Wear Test  (ASTM D-2882) 60 mg Maximum 
The following fluids work well over a wide temperature 
range, allow moisture to settle out and resist biological 
growth that may occur in cool operating hydraulic circuits.  
These fluids are recommended by Stanley.  Other fluids 
that meet or exceed the specifications of these fluids may 
also be used.
Chevron AW-MV-32
Exxon "Univis" J-26
Mobil D.T.E. 13
Gulf "Harmony" AW-HVI-150-32
Shell "Tellus" T-32
Texaco "Rando" HD-AZ
Union "Unax" AW-WR-32
Terresolve EnviroLogic 132
5. HYDRAULIC CONNECTIONS 
The recommended hose length is 25 ft/8 m with a 1/2 
inch/12.7 mm inside diameter.  The hoses must have a 
working pressure rating of at least 2500 psi/175 bar.  Each 
hose end must have male thread ends compatible with 
H.T.M.A. (HYDRAULIC TOOL MANUFACTURERS AS-
SOCIATION) quick disconnect fittings (NPT type threads).  
(See Figure 2.)
Figure 1. Control Panel
Facing the control panel, the bottom male quick disconnect 
fitting is the PRESSURE FLUID OUT fitting. The top female 