Electrical Connection - U.S.A. Only
1. Disconnect power.
2. Remove the terminal block cover screws and disengage 
mounting tabs to remove terminal block cover from back of 
range. 
3. Add power supply cord strain relief .
Assemble a UL listed strain relief in the opening.
Tighten strain relief screw against the power supply cord. 
4. Complete installation following instructions for your type of 
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
30" (76.2 cm) and 36" (91.4 cm) Models
48" (121.9 cm) Models
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 50 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
A. Phillips head screws
B. Terminal block cover
C. Two mounting tabs at bottom
A
B
C
A. UL listed strain relief
A