Regency I31-3 Gas Fireplace Inbuilt
GAS CONNECTION
3) Locate the center point where the flue will
pass through the chimney above the appli-
ance.  Move the appliance into the exact
location where it is to be installed.  Ensure
that the Insert is level.
4) The installer must provide a valve with a
plugged tapping, accessible for  test  gauge
connection, immediately upstream of the
gas supply connection to the appliance.
CAUTION: If the glass is removed or
opened  for servicing, it must be re-
placed and closed prior to operating the
appliance. The glass must be fixed in the
door when operating.
GAS CONNECTION WARNING:
Only persons licensed to work with
gas piping may make the neces-
sary gas connections to this appli-
ance.
1) If the appliance is to be installed into an
existing chimney system, thoroughly clean
the masonry or factory built fireplace.
2) The gas connection is 12" BSP.
SPECIFICATIONS
INSTALLATION
NOTE: Mantel clearances for Installation
into a Zero Clearance Kit are differ-
ent. Please refer to the Zero Clear-
ance Kit Manual for details.
Mantel Clearances with
Bay and Flush Louvres in
Masonry Installation
MINIMUM FIREPLACE
DIMENSIONS
The minimum fireplace dimensions for the Re-
gency gas space heater are shown in the
following diagrams:
Note: A  non-combustible mantel may
be installed at a lower height if the
framing is made of metal studs
covered with a non-combustible
board.
MINIMUM
CLEARANCES TO
COMBUSTIBLES
The minimum fireplace clearances for the Re-
gency gas space heater are shown in the
following diagrams:
      From Unit
Sides
255 mm
Ceiling
1205 mm
Mantle
see Mantel
Clearances
                     From Surround
                  (660 mm x 1016 mm)
Max. Mantle Depth
305 mm
Hearth Height
0 mm
Hearth Depth
I
405 mm
Hearth Width
1015 mm
Min. Alcove Width
1220 mm
Max. Alcove Depth
915 mm
NG
LPG
INJECTOR
  #37
#52
SIZE
2.65mm
1.6mm
INPUT
Min. 17 mj/h
Min. 17 mj/h
RATING
Max. 31 mj/h
Max. 31 mj/h
MANIFOLD
PRESSURE Max. 0.9 kPa
Max. 2.59 kPa