INSTALLATION
INSTALLATION IN MASONRY OR ZERO CLEARANCE CHIMNEY
1)  Measure and record dimensions to determine total 
Flex Liner length requirements (see instructions below 
for details).
2)  Carefully feed the liner down the chimney (masonry 
or zero clearance) and out through the damper.  One 
person should feed the liner through the chimney, and 
another person should pull the liner from the bottom.
3)  After carefully feeding the Flex Liner down the chim-
ney to the bottom, form and angle to line up the Flex 
Liner with the vent opening on the appliance.
Important:  Do not let the Flex Liner sag below the level 
at which it will connect to the appliance or connector.  
This could allow hot gas to become trapped and poten-
tially become a fi re hazard.  The Flex Liner path should 
always be sloped up toward the Termination Cap.
4)  Temporarily secure the Flex Liner at the top of the 
chimney.  Be sure to leave 2-3 inches of  fl ex above the 
existing chimney to allow for connection to the Termina-
tion Kit (Baseplate and Adaptor).
5)  Repeat Steps 1-4 for second length of Flex Liner.
6)  At the top of the chimney, slide the Baseplate over 
the tow ends of the Flex Liner and secure it to the sur-
rounding masonry using masonry anchor bolts.  Before 
installing the baseplate, run a bead of non-hardening 
seal and between the Baseplate and the masonry to 
prevent moisture from entering the chimney.
Note: Verify that there is suffi cient room to mount the 
Baseplate on to the masonry.  You must have a level 
surface in order to install the Baseplate properly.
7)  Attach the Flex Liner ends at the top of the chimney 
to the Co-Linear to Co-Axial Adaptor.  Use four sheet 
metal screws to connect each Flex Liner run to the 
Adaptor.  
8)  Twist lock the Vertical Termination Cap to the Adap-
tor.
Note:  If you are planning to extend the height of the 
chimney using Direct Vent GS Pipe, please refer to the 
Direct Vent Installation Instructions for information con-
cerning the proper procedure and restrictions of Direct 
Vent Pipe.
Also, consult the appliance manufacturer for any height 
restrictions of the chimney.
  
9) Connect the Co-Linear Flex to the two outlets on the 
top of the appliance using four sheet metal screws each. 
See the appliance manufacturer's instructions for de-
tails.  Make sure the Flex Liners do not sag behind the 
appliance.  Finally, move the appliance into its appropri-
ate place.  Mount the Adaptor to the Baseplate using 
sheet metal screws.
51-76mm