Freedom SW Owner’s Guide
Battery Charging Reference
This section describes the  multistage charging algorithm (formula) of the 
Freedom SW.
Battery Types
Freedom SW charges flooded (or wet) lead-acid, Gel, AGM (absorbed 
glass mat), and custom batteries.
Flooded (or wet) batteries have removable battery caps for refilling 
with distilled water and testing the electrolyte.
Gel batteries have the electrolyte in the form of a gel rather than a 
liquid and do not require topping up. Gel batteries are sealed and the 
battery caps are not removable. 
AGM (Absorbed Glass Mat) batteries are similar to gel batteries 
except that the electrolyte is absorbed into a fiberglass matting.
Custom battery is configured by the dealer, factory, or service center 
for battery types other than those listed above.
Charge Algorithm Stages
Three-Stage charging
If three-stage charging is enabled, the Freedom SW will charge batteries in 
a sequence known as three-stage charging. Whenever qualified AC power 
is present at the inverter’s input, it passes power through to the connected 
load and begins charging the batteries. The charging voltage delivered to 
the battery depends on the battery’s:
type setting
temperature (by switch setting or battery temperature sensor)
state of charge
The three automatic stages are:
bulk
absorption
float
See Figure 32 for a graph of the three-stage charging profile.
There is a fourth stage, equalization, which is initialized manually as it is 
only performed occasionally and only on flooded (or wet) batteries.
RISK OF BATTERY DAMAGE
Since the Freedom SW can only select one battery type setting for all 
batteries connected to its bank, do not mix battery types. All connected 
batteries should either be: Flooded (or wet) or Gel or AGM or Custom.
Failure to follow these instructions can damage the unit and/or 
damage other equipment.
Freedom SW 3K2K InvChg Owners Guide.book  Page 58  Wednesday, October 9, 2013  1:34 PM