BLDV7 Series Gas Fireplace
requirements for the Commonwealth of 
Massachusetts
This product must be installed by a licensed plumber or 
gas  fitter  when  installed  within  the  Commonwealth  of 
Massachusetts.
note regarding Vented products
Flex line installation must not exceed 36 inches and must 
have a T shutoff valve.
Any residence with a direct vent product must have a CO 
detector installed in the residence.
Installation of the fireplace or vented gas log in the State 
of Massachusetts requires the damper to be permanently 
removed or welded in the fully open position.
In addition, neither a naturally vented gas log nor a vent-
free product may be installed in a bedroom or bathroom in 
the State of Massachusetts.
All gas fitting and installation of this heater shall only be 
done by a licensed gas fitter or licensed plumber.
For all side wall horizontally vented gas fueled equipment 
installed  in  every  dwelling,  building  or  structure  used  in 
whole or in part for residential purposes, including those 
owned or operated by the Commonwealth and where the 
side wall exhaust vent termination is less than seven (7) feet 
above finished grade in the area of the venting, including but 
not limited to decks and porches, the following requirements 
shall be satisfied:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented 
gas fueled equipment, the installing plumber or gas fitter 
shall observe that a hard wired carbon monoxide detector 
with an alarm  is installed on each additional level of the 
dwelling,  building  or  structure  served  by  the  side  wall 
horizontal  vented  gas  fueled  equipment.  It  shall  be  the 
responsibility of the property owner to secure the services 
of qualified licensed professionals for the installation of hard 
wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fueled 
equipment is installed in a crawl space or an attic, the hard 
wired  carbon  monoxide  detector  with  alarm  and  battery 
back-up may be installed on the next adjacent floor level.
In the event that the requirements of this subdivision can not 
be met at the time of completion of installation, the owner 
shall have a period of thirty (30) days to comply with the 
above requirements; provided, however, that during said 
thirty (30) day period, a battery operated carbon monoxide 
detector with an alarm shall be installed.
approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance 
with the above provisions shall comply with NFPA 70 and 
ANSI/UL 034 listed and IAS certified.
Signage
A metal or plastic identification plate shall be permanently 
mounted to the exterior of the building at a minimum height 
of eight (8) feet above grade directly in line with the exhaust 
vent terminal for the horizontally vented gas fueled heating 
appliance or equipment. The sign shall read, in print size no 
less than one-half (1/) inch in size, “GaS Vent DIreCtLy 
BeLow, Keep CLear oF aLL oBStruCtIonS”.
Inspection
The state or local gas inspector of the side wall horizontally 
vented  gas  fueled  equipment  shall  not  approve  the 
installation unless, upon inspection, the inspector observes 
carbon  monoxide  detectors  and  signage  installed  in 
accordance  with  the  provisions  of  48  CMR  5.08()(a)1 
through 4.
exemptions
The  following  equipment  is  exempt  from  48  CMR 
5.08()(a)1 through 4:
• 
The equipment listed in Chapter 10 entitled “Equipment 
Not Required To Be Vented” in the most current edition 
of NFPA 54 as adopted by the Board; and
• 
Product Approved  side  wall  horizontally  vented  gas 
fueled  equipment  installed  in  a  room  or  structure 
separate from the dwelling, building or structure used 
in whole or in part for residential purposes.
ManuFaCturer requIreMentS
Gas equipment Venting System provided
When  the  manufacturer  of  Product Approved  side  wall 
horizontally  vented  gas  equipment  provides  a  venting 
system  design  or  venting  system  components  with  the 
equipment, the instructions provided by the manufacturer 
for  installation  of  the  equipment  and  the  venting  system 
shall include:
• 
Detailed instructions for the installation  of the venting 
system design or the venting system components; and
• 
A complete parts list for the venting system design or 
venting system.
Gas equipment Venting System not provided
When the manufacturer of a Product Approved side wall 
horizontally vented gas fueled equipment does not provide 
the parts for venting the flue gases, but identifies “special 
venting  systems”,  the  following  requirements  shall  be 
satisfied by the manufacturer:
• 
The  referenced  “special  venting  system”  instructions 
shall  be  included  with  the  appliance  or  equipment 
installation instructions; and
• 
The  “special  venting  systems”  shall  be  Product 
Approved  by  the  Board,  and  the  instructions  for  that 
system shall include a parts list and detailed installation 
instructions.
A copy of all installation instructions for all Product Approved 
side  wall  horizontally  vented  gas  fueled  equipment,  all 
venting instructions, all parts lists for venting instructions, 
and/or  all  venting  design  instructions  shall  remain  with 
the  appliance  or  equipment  at  the  completion  of  the 
installation.