Troubleshooting
Troubleshooting
The status of the indicators lets you know the current operational status of the projector. This 
section provides details about indicators.
z “POWER” in the following table stands for the “POWER/STANDBY” indicator.
Normal Operation Indicators
Error Indicators and Warning Messages
When an error occurs, wait until cool down is complete and the fan stops before unplugging the 
AC power cord. If you unplug the AC power cord while the fan is still operating, an error may 
occur when you plug the AC power cord back in.
Indicators
When this indicator:
Is this:
It means this:
POWER :
Amber steady
You have just plugged the AC power cord into a power 
outlet. Wait until the projector enters the standby state 
(see below) before trying to turn on power.
TEMP :
Amber steady
LAMP :
Amber steady
POWER :
Amber steady
Standby state: The AC power cord is plugged in and 
the projector is in standby.
POWER :
Green flashing
Projector is warming up after being turned on.
POWER :
Green steady
Projector is on and standing by for use.
POWER :
Amber flashing
Projector is cooling down after being turned off. If the 
projector is hot when you plug the AC power cord into 
a power outlet, it also goes into a cool down state.
LAMP :
Green steady
The projector’s Eco Mode is turned on.
Indicator/Error Message 
Description and Required Action 
POWER
TEMP
LAMP
: Green steady
: –
: –
The projector’s internal temperature is very high. Press the 
[ESC] key to clear the warning message and perform the 
following steps. 

Check for any blocking of the projector’s intake vents and 
exhaust vents, and make sure that there is sufficient space 
around the projector. 

If there is dust accumulated around the intake vents and/or 
exhaust vents, turn off the projector and remove it. 
Message : Internal temperature 
is too high. Check 
projector air vents for 
blockage. 
LAMP indicator
POWER/STANDBY indicator
TEMP indicator
ASK M9_UG_E.book  Page 16  Tuesday, October 23, 2007  5:32 PM