KitchenAid KESS907SSS 用户手册

下载
页码 24
7
Check with a qualified electrical installer if you are not sure 
the range is properly grounded.
*The NEC calculated load is less than the total connected load 
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with 
kit. For 50-amp rated cord kits, use kits that specify use with a 
nominal 1
³⁄₈" (34.9 mm) diameter connection opening.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a CSA International Certified 
Power Cord intended to be plugged into a standard 14-50R 
wall receptacle. Be sure the wall receptacle is within reach of 
range’s final location.
Do not use an extension cord.
Countertop Preparation
(for Slide-in Ranges Only)
The cooktop sides of the slide-in range fit over the cutout edge of 
your countertop.
If you have a square finish (flat) countertop and the opening width 
is 30" (76.2 cm), no countertop preparation is required.
Formed front-edged countertops must have molded edge 
shaved flat 
³⁄₈" (1.0 cm) from each front corner of opening.
Tile countertops may need trim cut back 
³⁄₈" (1.0 cm) from each 
front corner and/or rounded edge flattened.
If countertop opening width is greater than 30" (76.2 cm), adjust 
the 
³⁄₈" (1.0 cm) dimension.
Countertop must be level. Place level on countertop, first side to 
side, then front to back. If countertop is not level, range will not 
be level. Range must be level for satisfactory baking conditions.
INSTALLATION 
INSTRUCTIONS
Unpack Range
1. Remove shipping materials, tape and protective film from the 
range. Keep cardboard bottom under range. Remove oven 
racks and parts package from inside oven.
2. To place range on its back, take 4 cardboard corners from the 
carton. Stack one cardboard corner on top of another. 
Repeat with the other 2 corners. Place them lengthwise on 
the floor behind the range to support the range when it is laid 
on its back. Using 2 or more people, firmly grasp the range 
and gently lay it on its back on the cardboard corners.
3. Pull cardboard bottom firmly to remove.
Measure for Proper Height
Slide-In Ranges:
1. Measure the distance of the countertop to the floor. Measure 
at all 4 locations corresponding to the 4 corners of the 
underside of the range cooktop, as shown. 
2. Measure from the floor to the underside of the range cooktop.
3. Your leveling height will be the difference between the 
2 measurements you have just taken.
Range Rating*
Specified Rating of 
Power Supply Cord Kit 
and Circuit Protection
120/240 Volts
120/208 Volts
Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50**
50
30"
(76.2 cm)
30 ¾"
(78.1 cm)
³⁄₈"
(1.0 cm)
Measure at locations marked A, B, C, D.
A. Distance from floor to underside of range cooktop
B. Range side frame
C. Cooktop
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
A
C
D
B
B
C
A