Water Filtration System Location 
Requirements
(on some models)
For best results, do not install the water filtration system outside, 
or in extreme hot or cold temperatures. Temperature of water 
supply to the water filtration system must be between 40°F/4°C 
and 100°F/38°C. Do not install on hot water supply line.
Locate the water filtration system near the cold water supply pipe 
under the kitchen sink to filter cold water. 
Make sure that the water filter assembly is installed in the upright 
position.
It will be necessary to drill a ½" (1.3 cm) minimum diameter hole 
in the upper right or left rear corner of the side wall of the cabinet 
under the sink to route the water supply tubing through to the 
range.
Depending on your installation configuration, more routing holes 
may be required. 
Coil enough flexible codes approved water supply tubing behind 
the range to allow for the connection to the range to be made 
behind the range prior to setting the range in place.
Typical Installation Configuration
NOTE: For unique installations contact a licensed plumber.
In Massachusetts a licensed plumber is required and the 
Commonwealth of Massachusetts Plumbing Code 248-CMR 
shall be adhered to.
Water Supply Requirements
A cold water supply with water pressure between 30 and 120 psi 
(207 and 827 kPa) is required to operate the steam feature. In 
Massachusetts, plumbing code 248 CMR 3.00 and 10.00 must 
be followed and a licensed plumber shall be used. If you have 
questions about your water pressure call a licensed, qualified 
plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a 
reverse osmosis system going to the water inlet valve of the 
range needs to be between 30 and 120 psi (207 and 827 kPa).
If a reverse osmosis water filtration system is connected to your 
cold water supply, the water pressure to the reverse osmosis 
system needs to be a minimum of 40 psi (276 kPa).
If the water pressure to the reverse osmosis system is less than 
40 psi (276 kPa):
Check to see whether the sediment filter in the reverse 
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill 
after heavy usage.
If you have questions about your water pressure, call a licensed, 
qualified plumber.
Electrical Requirements - U.S.A. Only
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from: 
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269.
WARNING: Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. Check with a 
qualified electrician or service technician if you are in doubt as to 
whether the appliance is properly grounded. Do not modify the 
power supply cord plug. If it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
Range must be connected to the proper electrical voltage 
and frequency as specified on the model/serial number rating 
plate. The model/serial number rating plate is located on the 
right vertical surface of the oven door frame. Refer to the 
figures in the “Product Dimensions” section of the “Location 
Requirements” section.
Use a 4-wire power supply cord rated at 250 volts, 
40 or 50 amps and investigated for use with ranges.
*The NEC calculated load is less than the total connected load 
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with 
kit. For 50-amp rated cord kits, use kits that specify use with a 
nominal 1
³⁄₈" (34.9 mm) diameter connection opening.
A circuit breaker is recommended.
Wire sizes and connections must conform with the rating of 
the range.
The Tech Sheet is located in the console in a clear plastic 
bag.
Cold  water
supply
Hot Cold
Filter
assembly
location
Range Rating*
Specified Rating of Power 
Supply Cord Kit and 
Circuit Protection
120/240 Volts
120/208 Volts
Amps
Range Size
8.8 - 16.5 kW
16.6 - 22.5 kW
7.8 - 12.5 kW
12.6 - 18.5 kW
40 or 50**
50
30” (76.2 cm), 
36” (91.4 cm)
48” (121.9 cm)