4. Using the final measurement from Step 3, measure from the 
floor up and mark a horizontal line on the wall where a wall 
stud is located.
5. Position top of anti-tip bracket at line marked in Step 4 and 
mark holes. Drill two 
¹⁄₈" holes at the positions marked on the 
wall. Use screws provided to fasten anti-tip bracket to wall.
Anti-tip bracket must be mounted securely to stud in wall 
behind the range. Depending on thickness of the wall, longer 
screws may be required. Longer screws are available from 
your local hardware store.
Make Electrical Connection
This range must be connected to a grounded, metallic permanent 
wiring system or a ground connector should be connected to the 
ground terminal or wire lead on the range.
This range is manufactured with a frame connected, green or 
bare ground wire. Connect the range cable to the junction box 
through the UL listed or CSA approved conduit connector.
Electrical Connection Options
4-Wire Cable from Power Supply
IMPORTANT: Use the 4-wire cable from power supply where 
local codes do not permit connecting the frame-ground 
conductor to the neutral (white) junction box wire.
1. Disconnect power.
2. Remove junction box cover if present.
3. Connect the flexible armored cable from the range to the 
junction box using a UL listed or CSA approved conduit 
connector.
4. Tighten screws on conduit connector if present.
5. Connect the two black wires together using the UL listed wire 
nuts.
6. Separate the factory-crimped bare and white range wires.
7. Connect the two white wires together using the UL listed wire 
nuts.
8. Connect the green or bare ground wire from the range cable 
to the green or bare grounded wire (in the junction box) using 
the UL listed wire nuts.
9. Install junction box cover.
10. Reconnect power.
A. Horizontal line marked from Step 4.
B. Wall stud
C. Mounting screws
D. Anti-tip bracket
A
B
C
D
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground range.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
If your home has:
And you will be 
connecting to:
Go to Section:
4-wire direct
A fused 
disconnect or 
circuit breaker 
box
4-Wire Cable from 
Power Supply
3-wire direct
A fused 
disconnect or 
circuit breaker 
box
3-Wire Cable from 
Power Supply
A. Cable from power supply
B. Red wires
C. Green (or bare) ground wires
D. 4-Wire cable from range
E. Junction box
F. White wires
G. UL listed wire nuts
H. Black wires
I. UL listed or CSA approved 
conduit connector
(12.7 cm)
5"
(8.9 cm)
3
¹⁄₂
"
A
B
C
D
E
F
G
H
I