Bunn FMD-3 用户指南

下载
页码 42
32
SERVICE (cont.)
OVERFLOW PROTECTION SWITCH
P1637
FIG. 26 OVERFLOW PROTECTION
SWITCH LEADS
P1212
RED to BLK Wire
from Main Harness
RED to BLU Lead 
from Main Harness
FIG. 25 OVERFLOW PROTECTION SWITCH
Location:
 
The overflow protection switch is located inside 
the copper overflow cup on the left side of the tank.
Test Procedures:
1.  Disconnect  the  dispenser  from  the  power 
source.
2.  Remove the wire nuts connecting the red wires 
from the overflow protection switch to the black 
wire  and blue wire from the main harness.
3.  Check for continuity across the safety overflow 
switch red wires only until the plastic float is raised 
and check that continuity returns when the plastic 
float is again lowered.
If continuity is present as described, reconnect the 
red wires to the black wire  and the blue wire from 
the main harness.
If continuity is not present as described, replace the 
overflow protection switch.
29170 080900
Removal and Replacement:
1.  Disconnect the red leads from the overflow protec-
tion switch from the black wire and the blue wire 
from the main harness.
2.  Remove  the  nut  beneath  the  copper  overflow 
cup.
3.  Remove  the  entire  switch  assembly  from  the 
cup.
4.  Place the new switch assembly into the cup, wires 
first. Make sure that a gasket is in place around 
the threaded switch stem.
NOTE - The magnets must be at the top of float and 
there must be NO adjusting washers installed for the 
overflow protection switch to operate properly.
5.  Install the nut beneath the copper overflow cup. 
Be sure not to overtighten.
6.  Refer to Fig. 26 when reconnecting wires.