SERVICE (cont.)
LIMIT THERMOSTAT
FIG. 23 LIMIT THERMOSTAT
P2635
Location:
 
The limit thermostat is located in the center of the 
tank lid.
Test Procedures:
1.  Disconnect  the  dispenser  from  the  power 
source.
2.  Disconnect both black wires from the limit ther-
mostat.
3.  Check for continuity across the limit thermostat 
terminals.
If continuity is present as described, the limit thermostat 
is operating properly.
If continuity is not present as described, replace the 
limit thermostat.
FIG. 24 LIMIT THERMOSTAT TERMINALS
P1800
BLK to Tank Heater
BLK to Control
Thermostat
35135 012103
Removal and Replacement:
1.  Remove all wires from the limit thermostat ter-
minals.
2.  Carefully slide the limit thermostat out from under 
the retaining clip and remove the limit thermo-
stat.
3.  Carefully slide the new limit thermostat into the 
retaining clip.
4.  Refer to Fig. 24 when reconnecting the wires.