FIG. 10 THERMOSTAT WIRING
BLU/BLK to Limit Thermostat
BLK to Terminal Block
P1782
SERVICE (cont.)
Thermostat
Location: The mechanical thermostat is located inside 
the upper rear panel. To test the thermostat, access will 
also be needed to the terminal block located inside the 
bottom access panel.
Test Procedure: 
1.  Disconnect the dispenser from the power source.
2.  Check  the  voltage  across  the  black  wire  on  the 
thermostat and the white or red wire at the terminal 
block with a voltmeter. Connect the dispenser to the 
power source. The indication must be:
 
a.) 100 to 120 volts ac for 100 to 120 volt mod-
els,
 
b.) 200 to 240 volts ac for 200 to 240 volt mod-
els,
 
c.) 230 volts ac for 230 volt models.
3.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the Wiring 
Schematics and check the dispenser wiring harness.
4.  Check the voltage across the blue/black wire on 
the  thermostat  and  the  white  or  red  wire  at  the 
terminal  block  with  a  voltmeter  when  the  ther-
mostat is turned “ON” (fully clockwise). Connect 
the dispenser to the power source. The indication 
must be as described in step 2. Voltage must not 
be indicated when the thermostat is turned “OFF” 
(fully counterclockwise).
5.  Disconnect the dispenser from the power source.
P1781
If voltage is present as described, the thermostat is 
operating properly.
If  voltage  is  not  present  as  described,  replace  the 
thermostat.
Removal and Replacement: 
1.  Remove  both  wires  from  the  thermostat  termi-
nals.
2.  Remove the top lid from the dispenser to gain ac-
cess to the thermostat bulb.
3.  Remove the thermostat bulb by firmly pulling up on 
the capillary tube at the tank. This will disengage 
the grommet from the tank.
4.  Remove the two #6-32 screws holding the thermo-
stat to the mounting bracket.
5.  Fasten the new thermostat to the mounting brack-
et.
NOTE: Make sure that the capillary tube is away from 
any electrical termination and is not kinked.
6.  Slide the grommet to the red mark on the capillary 
tube.
7.  Insert the bulb through the hole in the tank and 
press the grommet firmly and evenly so that the 
groove in the grommet fits into the tank.
8.  Refer to FIG. 10 when reconnecting the wires.
9.  Readjust the thermostat dial as required.