Omnitron iConverter 10FL/T 8302-0 产品宣传页

产品代码
8302-0
下载
页码 2
Ordering inFOrmatiOn
Page 2
800-675-8410 • 949-250-6510  •  www.omnitron-systems.com  •  info@omnitron-systems.com  •  140 Technology Dr. Irvine, CA 92618
iConverter
 10FL/T 
© 2010 Omnitron Systems Technology, Inc.  All rights reserved.  iConverter and NetOutlook are Registered Trademarks of Omnitron Systems Technology, Inc.  
Trademarks are owned by their respective companies.  Specifications are subject to change without notice.
091-18300-004F 
9/10
speciFicatiOns
management
Model Type
10FL/T
Protocols
10BASE-FL, 10 BASE-T
UTP Connectors
RJ-45
Fiber Connectors
SC, ST, LC, MT-RJ, Single-Fiber SC
Controls
LS/LP, RFD
LED Displays
Power, F/O Link, UTP Link
Dimensions
W:0.85" x D:4.5" x H:2.8"
Weight
8 oz.
Compliance
UL, CE, FCC Class A, NEBS Level 3
Power Requirement
0.5A @ 3.3VDC (typical)
Temperature
           Standard:    0 to 50º C
                Wide:    -40 to 60º C
            Storage:    -40 to 80º C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4000m
MTBF (hrs)
830,000
Management of the plug-in module is accomplished by using 
a  Management  Module  (such  as  an  iConverter  NMM2  or 
10/100M2) that provides monitoring, configuration and trap 
notification.  The management module can be accessed via 
SNMP, Telnet, or serial port.  The SNMP-based management 
is  accomplished  via  Omnitron’s  intuitive,  graphic-oriented 
NetOutlook®  management  software  or  third  party  SNMP 
management  software,  while  the  Telnet  and  the  serial 
interfaces have an easy-to-use, menu-driven interface.
Real-time 10FL/T parameters that can be monitored include 
power,  link,  data  receive  status,  module  type  and  model, 
hardware and software revisions, serial numbers and a user-
defined identifier.
The user can override the 10FL/T module’s physical DIP-switch 
settings  by  using  SNMP  or Telnet  to  configure  DIP-switch-
selectable  parameters  such  as  Link  Propagate  or  Remote 
Fault Detection.
In  addition  to  all  standard  iConverter  SNMP  traps  such  as 
module  insertion  and  removal,  the  10FL/T  modules  can 
generate traps on port state changes including link-up and 
link-down. Trap monitoring of specific events can be selectively 
enabled or disabled by the network administrator.
Model Type
Fiber  /
Media
Type
Distance
Connector Types
Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
Min. Tx
Power
(dBm)
Max. Tx
Power
(dBm)
Min. Rx
Sensitivity
(dBm)
Max. Rx
Sensitivity
(dBm)
Link
Budget
(dBm)
ST
SC
MT-RJ
LC
10FL/T
Dual Fiber
MM
2km
8300-0
8302-0
-
-
850
850
-21
-11
-31
-11
10
MM
5km
8300-1
-
8304-1
-
1310
1310
-24
-14
-31
-14
7
SM
30km
8301-1
8303-1
8305-1
8307-1
1310
1310
-15
-8
-31
-8
16
SM
60km
8301-2
8303-2
-
8307-2
1310
1310
-5
0
-31
-3*
26
SM
120km
-
8303-3
-
8307-3
1550
1550
-5
0
-31
-3*
26
10FL/T
Single-Fiber
SM
20km
-
8310-1
-
-
1310
1550
-15
-5
-30
-3
15
SM
40km
-
8310-2
-
-
1310
1550
-8
0
-30
-3*
22
SM
20km
-
8311-1
-
-
1550
1310
-15
-5
-30
-3
15
SM
40km
-
8311-2
-
-
1550
1310
-8
0
-30
-3*
22
 For wide temperature (-40 to 60º C) modules, add a "W" to the end of the model number.  Consult factory for other configurations and extended temperature
 (-40 to +75º C) modules.
 When using single-fiber (SF) media converter models, the Tx wavelength on one end has to match the Rx wavelength on the other.