Omnitron iConverter 10FL/T 8302-0 产品宣传页
产品代码
8302-0
Ordering inFOrmatiOn
Page 2
800-675-8410 • 949-250-6510 • www.omnitron-systems.com • info@omnitron-systems.com • 140 Technology Dr. Irvine, CA 92618
iConverter
10FL/T
© 2010 Omnitron Systems Technology, Inc. All rights reserved. iConverter and NetOutlook are Registered Trademarks of Omnitron Systems Technology, Inc.
Trademarks are owned by their respective companies. Specifications are subject to change without notice.
091-18300-004F
9/10
speciFicatiOns
management
Model Type
10FL/T
Protocols
10BASE-FL, 10 BASE-T
UTP Connectors
RJ-45
Fiber Connectors
SC, ST, LC, MT-RJ, Single-Fiber SC
Controls
LS/LP, RFD
LED Displays
Power, F/O Link, UTP Link
Dimensions
W:0.85" x D:4.5" x H:2.8"
Weight
8 oz.
Compliance
UL, CE, FCC Class A, NEBS Level 3
Power Requirement
0.5A @ 3.3VDC (typical)
Temperature
Standard: 0 to 50º C
Wide: -40 to 60º C
Storage: -40 to 80º C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4000m
MTBF (hrs)
830,000
Management of the plug-in module is accomplished by using
a Management Module (such as an iConverter NMM2 or
10/100M2) that provides monitoring, configuration and trap
notification. The management module can be accessed via
SNMP, Telnet, or serial port. The SNMP-based management
is accomplished via Omnitron’s intuitive, graphic-oriented
NetOutlook® management software or third party SNMP
management software, while the Telnet and the serial
interfaces have an easy-to-use, menu-driven interface.
Real-time 10FL/T parameters that can be monitored include
power, link, data receive status, module type and model,
hardware and software revisions, serial numbers and a user-
defined identifier.
The user can override the 10FL/T module’s physical DIP-switch
settings by using SNMP or Telnet to configure DIP-switch-
selectable parameters such as Link Propagate or Remote
Fault Detection.
In addition to all standard iConverter SNMP traps such as
module insertion and removal, the 10FL/T modules can
generate traps on port state changes including link-up and
link-down. Trap monitoring of specific events can be selectively
enabled or disabled by the network administrator.
Model Type
Fiber /
Media
Type
Distance
Connector Types
Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
Min. Tx
Power
(dBm)
Max. Tx
Power
(dBm)
Min. Rx
Sensitivity
(dBm)
Max. Rx
Sensitivity
(dBm)
Link
Budget
(dBm)
ST
SC
MT-RJ
LC
10FL/T
Dual Fiber
MM
2km
8300-0
8302-0
-
-
850
850
-21
-11
-31
-11
10
MM
5km
8300-1
-
8304-1
-
1310
1310
-24
-14
-31
-14
7
SM
30km
8301-1
8303-1
8305-1
8307-1
1310
1310
-15
-8
-31
-8
16
SM
60km
8301-2
8303-2
-
8307-2
1310
1310
-5
0
-31
-3*
26
SM
120km
-
8303-3
-
8307-3
1550
1550
-5
0
-31
-3*
26
10FL/T
Single-Fiber
SM
20km
-
8310-1
-
-
1310
1550
-15
-5
-30
-3
15
SM
40km
-
8310-2
-
-
1310
1550
-8
0
-30
-3*
22
SM
20km
-
8311-1
-
-
1550
1310
-15
-5
-30
-3
15
SM
40km
-
8311-2
-
-
1550
1310
-8
0
-30
-3*
22
For wide temperature (-40 to 60º C) modules, add a "W" to the end of the model number. Consult factory for other configurations and extended temperature
(-40 to +75º C) modules.
When using single-fiber (SF) media converter models, the Tx wavelength on one end has to match the Rx wavelength on the other.