Installation Clearances
Venting Requirements 
(Vented Models Only)
Vent system must terminate to the outdoors except for 
non-vented (recirculating) installations.
Do not terminate the vent system in an attic or other 
enclosed area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use a 6" (15.2 cm) round metal vent or a 3
¹⁄₄" x 10" (8.3 
x 25.4 cm) rectangular metal vent. Rigid metal vent is 
recommended. Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should 
be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight 
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has 
a damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening around 
the cap.
Cold Weather Installations
An additional back draft damper should be installed to minimize 
backward cold air flow and a thermal break should be installed to 
minimize conduction of outside temperatures as part of the vent 
system. The damper should be on the cold air side of the thermal 
break.
The break should be as close as possible to where the vent 
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems 
when using ventilation systems greater than specified CFM of 
air movement. The specified CFM varies from locale to locale. 
Consult your HVAC professional for specific requirements in 
your area.
Venting Methods
The vent system for venting out of the top of range hood can 
be terminated either through the roof or wall. Use a 6" (15.2 cm) 
round vent. The vent system for venting out the rear of the range 
hood must be terminated through the wall. Use a 3
¹⁄₄" x 10" (8.3 
x 25.4 cm) rectangular vent. For rear venting the Damper 
Assembly/Motor Mounting Bracket Kit is required. See 
“Assistance or Service” section to order.
NOTE: Flexible vent is not recommended. Flexible vent creates 
back pressure and air turbulence that gently reduces 
performance. 
A. 18" (45.7 cm) min. clearance - upper cabinet to countertop
B. 24" (61.0 cm) min. for electric cooking surfaces
27" (68.6 cm) min. for gas cooking surfaces
30" (76.2 cm) suggested max. - bottom of range hood 
to cooking surface
C. 30" (76.2 cm) or 36" (91.4 cm) min. cabinet opening width
D. 12" (30.5 cm) min. cabinet depth
E. 36" (91.4 cm) base cabinet height
A
B
C
D
E
Roof Venting
Wall Venting
A. 6" (15.2 cm) round vent 
through roof
B. Round vent: 6" (15.2 cm) 
diameter transition piece.
C. 24" (61.0 cm) - 30" (76.2 cm) 
above electric cooking surface
27" (68.6 cm) - 30" (76.2 cm) 
above gas cooking surface
D. Roof cap
A. 6" (15.2 cm) round vent 
through the wall
B. 3
¹⁄₄" x 10" (8.3 x 25.4 cm) 
through the wall (purchased 
separately)
C. 24" (61.0 cm) - 30" (76.2 cm) 
above electric cooking surface
27" (68.6 cm) - 30" (76.2 cm) 
above gas cooking surface
D. Wall cap
A
C
B
D
A
B
C
D