Complete Preparation
1. Determine the required height for the home power supply 
cable and drill a 1¼" (3.2 cm) hole at this location.
2. Run the home power supply cable according to the National 
Electrical Code or CSA Standards and local codes and 
ordinances. There must be enough ½" conduit and wires from 
the fused disconnect (or circuit breaker) box to make the 
connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
3. Remove the grease filters. See the “Range Hood Care” 
section.
4. Remove terminal box cover and set aside.
5. Remove knockout from the top of the vent hood and install a 
UL listed or CSA approved ½" strain relief.
Install Range Hood
1. Depending on your installation, remove either top or rear 
rectangular vent knockout.
2. Remove tape from damper flap.
NOTE: The 3¼" x 10" (8.3 x 25.4 cm) rectangular damper can 
be installed up to 1" (2.5 cm) on either side of the hood center 
to accommodate off center duct work.
3. Attach the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent 
connector to the range hood using sheet metal screws.
NOTE: If the wall cap is directly behind the 3¼" x 10" (8.3 x 
25.4 cm) rectangular vent connector, check that the damper 
and the wall cap do not interfere with each other. Remove the 
damper from the 3¼" x 10" (8.3 x 25.4 cm) rectangular vent 
connector if they interfere. 
4. Using 2 or more people, lift the hood into final position. Feed 
enough electrical wire through the ½" UL listed or CSA 
approved strain relief to make connections in the terminal 
box. Tighten the strain relief screws. 
5. Position the range hood so that the large end of the keyhole 
slots are over the mounting screws. Then push the hood 
toward the wall (for cabinet mounting) or allow the range 
hood to slide down to the marked mounting height (for wall 
mounting) so that the screws are in the neck of the slots. 
Tighten the mounting screws, making sure the screws are in 
the narrow neck of slots. (For wall mount, check that the 
hood is level). 
6. Connect ventwork to hood. Seal joints with clamps to make 
secure and airtight.
7. Check that back draft dampers work properly.
Make Electrical Connection
1. Disconnect power. 
2. Use UL listed wire connectors and connect white wires (A) 
together.
3. Use UL listed wire connectors and connect black wires (B) 
together.
A. Vent knockouts
A. Top venting
B. Sheet metal screws
C. Hinge pin
D. Vent knockouts
E. Rear venting
A
A
B
C
D
C
B
E
A. White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) and yellow-green ground wire
E. Home power supply cable
F. UL listed or CSA approved ½" strain relief
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F