Venting Methods
This canopy hood is factory set for venting through the roof or 
wall.
A 6" (15.2 cm) round vent system is needed for installation (not 
included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent 
creates back pressure and air turbulence that greatly reduce 
performance.
Vent system can terminate either through the roof or wall. To 
vent through a wall, a 90° elbow is needed.
Rear Discharge
A 90° elbow may be installed immediately above the hood. 
For Non-Vented (Recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the 
outside, the hood can be used in the non-vented (recirculating) 
version, using a Recirculation Kit (which includes charcoal 
filters and a deflector). To order, see the “Assistance or Service” 
section.
Roof Venting
Wall Venting
Non-Vented 
(Recirculating)
Calculating Vent System Length
To calculate the length of the system you need, add the 
equivalent feet (meters) for each vent piece used in the system.
Vent Piece
6" (15.2 cm) Round
45° elbow
2.5 ft 
(0.8 m)
90° elbow
5.0 ft 
(1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
Example Vent System
The following example falls within the maximum recommended 
vent length of 35 ft (10.7 m).
1 - 90° elbow
5.0 ft (1.5 m)
1 - wall cap
0.0 ft (0.0 m)
8 ft (2.4 m) straight
8.0 ft (2.4 m)
Length of system
13.0 ft (3.9 m)
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 
(latest edition), or CSA Standards C22.1-94, Canadian Electrical 
Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local 
codes and ordinances.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association 
1 Batterymarch Park 
Quincy, MA 02169-7471
CSA International 
8501 East Pleasant Valley Road 
Cleveland, OH 44131-5575
 
A 120-volt, 60 Hz., AC-only, 15-amp, fused electrical circuit 
is required.
 
If the house has aluminum wiring, follow the procedure 
below:
1.  Connect a section of solid copper wire to the pigtail 
leads.
2.  Connect the aluminum wiring to the added section 
of copper wire using special connectors and/or tools 
designed and UL Listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.
 
Wire sizes and connections must conform with the rating of 
the appliance as specified on the model/serial/rating plate. 
The model/serial/rating plate is located behind the left filter 
on the rear wall of the range hood.
 
Wire sizes must conform to the requirements of the National 
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA 
Standards C22. 1-94, Canadian Electrical Code, Part 1 and 
C22.2 No. 0-M91 (latest edition) and all local codes and 
ordinances.
A
A
B
B
B
A
A.  Roof cap
B.  6" (15.2 cm) 
round vent
A.  Wall cap
B.  6" (15.2 cm) 
round vent
A. Deflector
B.  6" (15.2 cm) 
round vent
90  elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap