Make Electrical Connection
1.  Disconnect power.
2.  Remove terminal box cover.
3.  Remove the knockout in the terminal box and install a UL 
Listed or CSA Approved 
1
/
2
" strain relief.
4.  Run home power supply wiring through 
1
/
2
" strain relief into 
terminal box.
5.  Use UL Listed wire connectors and connect white wires (B) 
together.
6.  Use UL Listed wire connectors and connect black wires (C) 
together.
7.  Connect green (or bare) ground wire from home power 
supply to the 2 yellow-green ground wires (D) in terminal box 
using UL Listed wire connectors.
8.  Tighten strain relief screw.
9.  Install terminal box cover.
10. Reconnect power.
Optional Power Cord Kit Installations
For optional power cord kit installations, follow the instructions 
supplied with the power cord kit. See the “Assistance or 
Service” section for information on ordering.
NOTE: Use only with range hood cord connection kits that have 
been investigated and found acceptable for use with this model 
range hood.
Install Vent Covers
1.  When using both upper and lower vent covers, push lower 
cover down onto hood and lift upper cover to ceiling and 
install with (2) 2.9 x 6.5 mm screws.
NOTE: For vented installations, the upper vent cover may be 
reversed to hide slots.
Complete Installation
1.  For non-vented (recirculating) installations only, install 
charcoal filters over grille on blower housing. See the “Range 
Hood Care” section.
2.  Install metal filters. See the “Range Hood Care” section.
3.  Check the operation of the range hood blower and light. See 
the “Range Hood Use” section.
NOTE: To get the most efficient use from your new range hood, 
read the “Range Hood Use” section.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
D
F
B
E
G
H
I
A.  Terminal box cover
B. Screws
C.  Home power supply
1
/
2
" UL Listed or CSA 
Approved strain relief
E.  Terminal box
F.  Black wires
G. White wires
H.  UL Listed wire 
connectors
I.  Green (or bare) wires 
connected to yellow-
green wires
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.
A
B
C
C
D
A.  Upper vent cover
B.  Lower vent cover
C.  2.9 x 6.5 mm screws
D. Bracket