Netgear GSM7328Sv2 - ProSAFE 24+4 Gigabit Ethernet L3 Managed Stackable Switch 管理员指南

下载
页码 486
318
   
|    
Chapter 18.  Switch Stacks 
 
ProSafe 7000 Managed Switch Release 8.0.3 
that occur when the switch stack compares the preconfigured configuration with the new 
switch.
Table 2.  Preconfigured Switches Compared to Stack Configuration
Switch Type Is the 
Same
Stack Member Number
Result
Yes
Is the same.
The switch stack applies configuration to the 
preconfigured new switch and adds it to the stack.
Yes
Does not match.
• The switch stack applies its default stack member 
number to the preconfigured switch and adds it to 
the stack.
• The stack member number configuration in the 
preconfigured switch changes to reflect the new 
information.
Is not found in the stack 
configuration.
• The switch stack applies the default configuration 
to the new switch and adds it to the stack.
• The preconfigured information is changed to reflect 
the new information.
Is not found in the 
preconfigured switch.
The switch stack applies the default configuration to 
the preconfigured switch and adds it to the stack.
Renumber Stack Members
This example is provided as CLI commands and a Web interface procedure.
CLI: Renumber Stack Members
Note:  
When issuing a command (such as move management, or 
renumber), NETGEAR recommends that you wait until the 
command has fully executed before issuing the next command. For 
example, if a reset is issued to a stack member, use the show port 
command to verify that the switch has re-merged with the stack, and 
all ports are joined before issuing the next command.
•     
If specific numbering is required, NETGEAR recommends that you assign stack members 
their numbers when they are first installed and configured in the stack, if possible.
•     
If the stack unit number for a switch is unused, you can renumber the unit by using the 
switch <oldunit-id> renumber <newunit-id>
 CLI command. This command is 
found in global config mode.
•     
If the newunit-id has been preconfigured, you might need to remove the newunit-id from 
the configuration before renumbering the unit.