6.  Position the broil burner against the roof of the oven cavity 
and attach with screw.
To Convert Surface Burners
1.  If the burner grates are installed, remove them.
2.  Remove the burner caps.
3.  Using a Phillips or TORX
®
 screwdriver, remove the burner 
base.
4.  Apply masking tape to the end of a 
9
/
32
" (7.0 mm) nut driver 
to help hold the Natural gas orifice spud in the nut driver 
while changing it. Press nut driver down onto the Natural gas 
orifice spud and remove by turning it counterclockwise and 
lifting out. Set the Natural gas orifice spud aside.
Use the following chart for correct LP gas orifice spud for each 
burner. Refer to the model/serial/rating plate behind the control 
panel for proper sizing of LP gas orifice spuds for each burner 
location.
LP Gas Orifice Spud Chart
Burner Rating
Color
Number
4,000 BTU
Blue
64L
7,000 BTU
Black
81L
9,100 BTU
Green
97L
14,000 BTU
Red
114L
5.  Replace the Natural gas orifice spud with the correct LP gas 
orifice spud. See the “LP Gas Orifice Spud Chart.”
6.  Replace burner base and hand tighten the screws.
7.  Replace burner cap.
8.  Repeat steps 1 through 7 for the remaining burners.
9.  Place Natural gas orifice spuds in plastic parts bag for future 
use and keep with literature package.
10. Replace burner grates.
11. Complete installation. See the “Make Gas Connection” and 
“Electronic Ignition System” sections.
Checking for proper cooktop burner flame is very important. 
The small inner cone should have a very distinct blue flame 
1
/
4
" to 
1
/
2
" long. The outer cone is not as distinct as the inner 
cone. LP gas flames have a slightly yellow tip.
IMPORTANT: You may have to adjust the LO setting for each 
cooktop burner. See “Adjust Flame Height” in the “Electronic 
Ignition System” section.
Natural Gas Conversion
1.  Turn manual shut-off valve to the closed position.
2.  Unplug range or disconnect power.
A
B
A.  Broil burner orifice hood
B.  Broil burner
A
B
C
D
A. Burner cap
B.Gas tube opening
C. Burner base screws
D. Burner base
A
A.  Natural gas orifice spud
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation 
instructions.
Slide range back so rear range foot is engaged in the 
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed 
and engaged.
Failure to follow these instructions can result in death 
or serious burns to children and adults.
A
B
C
A.  To range
B.  Shut-off valve (closed position)
C.  Gas supply line