KitchenAid 36" Island-Mount Canopy Hood 使用和维护

下载
页码 32
10
Install Chimney Covers
Vented Installation
1. Attach the vent system to the damper. Seal all joints with vent 
clamp.
2. Remove the plastic covering from the chimney covers.
3. Slide the upper chimney cover over the chimney support and 
attach to the top of the support using two screws provided.
4. Slide the lower chimney cover over the chimney support and 
the upper cover. Attach to the bottom of the support using 
the 2 screws provided.
Non-vented (recirculating) Installations
NOTE: Non-vented (recirculating) installation is not allowed over 
cooktops with BTU ratings of 60,000 or higher.
IMPORTANT: For this installation, you will need Recirculating Kit 
Part Number W10271502.
1. Remove the plastic covering from the chimney covers.
2. Slide the upper chimney cover over the chimney support and 
attach to the top of the support using two screws provided.
3. Place the 6" round vent extension over the exhaust outlet and 
push down to seat. Place the diverter over the vent extension 
and push down to seat. Check that the diverter exhaust 
outlets are parallel with the vent motor sides so that they will 
align with the vent cover openings in the lower chimney
.
4. Install the 2 vent extension pieces onto the diverter pushing 
them until they stop.
5. Discard the lower chimney cover shipped with the hood and 
use the cover from the Recirculating Kit (purchased 
separately).
6. Slide the Recirculating Kit lower chimney cover over the 
chimney support and the upper cover.
Check that the diverter extensions line up with the openings 
in the cover. Attach the cover using the 2 screws provided.
7. Snap vent grills into place.
A. Upper chimney cover
B. Lower chimney cover
C. Screw
A. Diverter
B. Vent motor
C. 6" (15.2 cm) round vent extension
A
B
C
A
B
C
A. Diverter
B. Exhaust extension
A. Vent grill location
A
B
A