KitchenAid 30'' Wall-Mount 600 CFM Canopy Hood, Architect® Series II 安装指南

下载
页码 32
9
Make Electrical Connection
1. Disconnect power.
2. Remove the terminal box cover.
3. Remove the knockout in the terminal box cover and install 
a UL listed or CSA approved
 ¹⁄₂" strain relief.
4. Run the power supply cable or power cord kit (see the 
“Accessories” section for information on ordering) through 
strain relief into terminal box.
5. Use UL listed wire connectors and connect the black 
wires (C) together.
6. Use UL listed wire connectors and connect the white 
wires (E) together.
7. Connect green (or bare) ground wire from the power supply or 
power cord kit to yellow-green ground wire (F) in terminal box 
using UL listed wire connectors.
8. Tighten the strain relief screw.
9. Install the terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
A. Knockout
B. Terminal box cover
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
A. Power supply cable or 
power cord kit
B. UL listed or CSA approved 
strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-
green ground wires
A
B
C
D
E
F
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.