KitchenAid 24" Wall-Mount Canopy 尺寸示意图

下载
页码 2
VENTING METHODS (cont.)
This canopy hood is factory set for venting through the roof or 
wall.
A 6" (15.2 cm) round vent system is needed for installation (not 
included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent 
creates back pressure and air turbulence that greatly reduce 
performance.
Vent system can terminate either through the roof or wall. To 
vent through a wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the 
outside, the hood can be used in the non-vented (recirculating) 
version, using a Recirculation Kit (which includes charcoal 
filters and a deflector). 
Calculating Vent System Length
To calculate the length of the system you need, add the 
equivalent feet (meters) for each vent piece used in the system.
Vent Piece
6" (15.2 cm) Round
45° elbow
2.5 ft (0.8 m)
90° elbow
5.0 ft (1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
Because Whirlpool Corporation policy includes a continuous commitment to improve our 
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see 
Installation Instructions packed with product. Specifications subject to 
change without notice.
W10444175C
03/2015
The following example falls within the maximum recommended 
vent length of 35 ft (10.7 m).
1 - 90° elbow
= 5.0 ft (1.5 m)
1 - wall cap
= 0.0 ft (0.0 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
Length of system
= 13.0 ft (3.9 m)
A
A
B
B
B
A
A. Roof cap
B. 6" (15.2 cm)
    round vent
A. Wall cap
B. 6" (15.2 cm)
    round vent
A. Deflector
B. 6" (15.2 cm)
    round vent
90  elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
Example vent system
Roof Venting
Wall Venting
Non-vented
(recirculating)
Page 2 of 2