Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10331006C
2/24/12
Page 2 of 2
NOTE: 
Wall venting can be an option for 2-story homes.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
Vent Piece 
6" (15.2 cm) Round
45° elbow 2.5 
ft
(0.8 m)
90° elbow 5.0 
ft
(1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
Non-vented (recirculating)
Roof Venting
A. Deflector
B. 6" (15.2 cm) round vent
A. Roof cap
B. 6" (15.2 cm) round vent
B
A
B
A
The following example falls within the maximum vent length of 35 ft
(10.7 m).
1 - 90° elbow 
= 5.0 ft (1.5 m)
1 - wall cap 
= 0.0 ft (0.0 m)
8 ft (2.4 m) straight 
= 8.0 ft (2.4 m)
System length
= 13.0 ft (3.9 m)
Example Vent System
90  elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the
hood can be used in the non-vented (recirculating) version, using a
Recirculation Kit (which includes charcoal filters and a deflector). To
order, see the “Assistance or Service” section.
NOTE: 
Wall venting can be an option for 2-story homes.