Install Range Hood
1. Remove screws from wooden shipping supports. Properly 
dispose of shipping materials.
2. Using 2 or more people, hang range hood on 2 mounting 
screws through the mounting slots on back of hood.
3. Remove the grease filter. See “Range Hood Care” section.
4. Level the range hood and tighten upper mounting screws.
5. Install (2) 5 x 45 mm #2 Phillips lower mounting screws 
and tighten. Use the optional wall anchors if needed.
Connect Vent System
1. Install transition on top of hood (if removed for shipping) with 
(2) 3.5 x 9.5 mm T10 sheet metal screws. Use T10 Torx
®
 drive 
(or T10 adapter provided) to tighten.
For vented installations only:
1. Fit vent system over transition piece.
2. Seal connection with clamps.
3. Check that back draft dampers work properly.
For non-vented (recirculating) installation only:
1. Assemble the air deflector with the duct cover bracket using 
(4) 4.2 x 8 mm T20
®
 screws. Use a T20
®
 Torx
®
 drive (or T20
®
 
adapter provided) to tighten.
2. Measure from the bottom of the air deflector to the bottom 
of the hood outlet.
3. Cut the duct to the measured size “X.”
4. Remove the air deflector.
5. Slide the duct onto the bottom of the air deflector.
6. Place the assembled air deflector and duct over the 
exhaust outlet from the hood.
7. Reassemble the air deflector to the duct cover bracket 
with the 4 assembly screws.
8. Seal connections with vent clamps.
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
A. Vent transition
B. 3.5 x 9.5 mm screw
A
C
B
B
A
A. Assembly screws
B. Air deflector
C. Duct cover bracket
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
A
B
C
X
A
C
D
B
E