6. Use UL listed wire connectors and connect white wires (E) 
together.
7. Connect green (or bare) ground wire from home power supply 
to yellow-green ground wire (F) in terminal box using UL listed 
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Install Vent Covers
When using both upper and lower vent covers, push lower cover 
down onto hood and lift upper cover to ceiling and install with 
two 4 x 8 mm screws.
NOTE: For vented installations the upper vent cover may be 
reversed to hide slots.
Secure the bottom of the duct with 2 - 4 x 8 mm screws.
Complete Installation
1. For non-vented (recirculating) installations only, install 
charcoal filters over grille on blower housing. See the “Range 
Hood Care” section.
2. Install metal filters. See the “Range Hood Care” section.
3. Check the operation of the range hood blower and light. See 
the “Range Hood Use” section.
NOTE: To get the most efficient use from your new range hood, 
read the “Range Hood Use” section.
RANGE HOOD USE
The range hood is designed to remove smoke, cooking vapors 
and odors from the cooktop area. For best results, start the hood 
before cooking and allow it to operate several minutes after the 
cooking is complete to clear all smoke and odors from the 
kitchen.
The range hood controls are located on the front side of the 
canopy.
A. Upper vent cover
B. Lower vent cover
C. 4 x 8 mm screws
D. Bracket
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.
A
B
C
D
A. Louver holes (non-vented 
[recirculating] installations only)
B. Duct covers
C. Lamp housings
D. Canopy
E. Grease filters
F. Grease filter handles
G. Control panel
B
C
D
E
F
A