KitchenAid 36" Wall-Mount Canopy Hood 尺寸示意图

下载
页码 2
*
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10268948C
11/16/09
Page 2 of 2
Non-vented (recirculating) Installations
For non-vented (recirculating) installations, optional Recirculation Kit Part
Number W10271501, must be used. This kit includes a new lower chimney
cover that replaces the lower chimney cover shipped with the range hood,
a diverter with extensions, 2 grids for inserting into the lower chimney, and
a charcoal filter.
overall chimney
height
Upper
chimney
11
¹³⁄₁₆
"
(30.0 cm)
10¼"
(26. 0 cm)
3
⁹⁄₁₆
(9.1 cm)
Vent 
opening
on each 
side
2⁷⁄₁₆
"
(6.2 cm)
5⁵⁄₁₆
"
(13.5 cm)
21¼"
(54.0 cm) 
lower
chimney
height
12⁵⁄₈
"
(32.0 cm)
25
⁵⁄₈
" (65.1 cm)
min.
37¼" (94.6 cm)
max.
INSTALLATION DIMENSIONS
18" (45.7 cm) min. 
clearance upper 
cabinet to countertop
X*
36" (91.4 cm) 
countertop height
See Note*
30" (76.2 cm) or 36" (91.4 cm)
cabinet opening width
(if installed between cabinets)
NOTE: 
The range hood chimneys are adjustable and designed to meet
varying ceiling or soffit heights depending on the distance “X” between the
bottom of the range hood and the cooking surface. For higher ceilings, a
Stainless Steel Chimney Extension Kit Part Number W10271503 is
available from your dealer or an authorized parts distributor. The chimney
extension replaces the upper chimney shipped with the range hood.
IMPORTANT: 
Minimum distance “X”: 30" (76.2 cm)
Suggested maximum distance “X”: 36" (91.4 cm)
Chimneys can be adjusted for ceilings between 8' 
³⁄₈" (2.55 m) and 9' 6"
(2.90 m) in both vented and non-vented (recirculating) applications.
If you have shorter ceilings, the upper chimney can be shortened by
removing up to 5
¹⁄₄" (13.3 cm) off the bottom for vented applications and
11
¹⁄₄" (28.6 cm) for non-vented (recirculating) applications. This will give
you a minimum ceiling height of 7' 8" (2.34 m).
NOTE: 
If the upper chimney is cut for your application, the lower
chimney bracket will not be used.
PRODUCT DIMENSIONS
Vented Installations
25
⁵⁄₈
" (65.1 cm)
min.
37¼" (94.6 cm)
max.
overall chimney
height
21¼"
(54.0 cm)
10¼"
(26. 0 cm)
30" (76.2 cm) model: 29
¹⁵⁄₁₆
" (76.0  cm)
36" (91.4 cm) model: 35
³⁄₈
" (89.9  cm)
Upper
chimney
Lower
chimney
11
¹³⁄₁₆
"
(30.0 cm)
4¾"
(12.1 cm)
19¼"
(48.9 cm)