Single Oven Installed in Cabinet
Cabinet Side View
Electrical Requirements
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.
It is not recommended to ground to a gas pipe.
Check with a qualified electrical installer if you are not sure the 
oven is properly grounded.
It is not recommended to have a fuse in the neutral or ground 
circuit.
This oven must be connected to a grounded metal, permanent 
wiring system.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/NFPA 
70-latest edition or CSA Standards C22.1-94, Canadian Electrical 
Code, Part 1 and C22.2 No. O-M91-latest edition, and all local 
codes and ordinances.
A copy of the above code standards can be obtained from:
 National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Electrical Connection
To properly install your oven, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
Oven must be connected to the proper electrical voltage and 
frequency as specified on the model/serial number rating 
plate. The model/serial number rating plate is located at the 
bottom of the right-hand mounting rail. See the following 
illustration.
Models rated at 7.2 kW and below at 240 volts (5.4 kW and 
below at 208 volts) require a separate 30-amp circuit.
A time-delay fuse or circuit breaker is recommended.
Connect directly to the fused disconnect (or circuit breaker 
box) through flexible, armored or nonmetallic sheathed, 
copper cable (with grounding wire). See “Make Electrical 
Connection” section. 
Flexible cable from appliance should be connected directly to 
the junction box.
Fuse both sides of the line.
Do not cut the conduit. The length of conduit provided is for 
serviceability of the oven.
A UL listed or CSA approved conduit connector must be 
provided.
If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the pigtail 
leads.
2. Connect the aluminum wiring to the added section of 
copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.
A.
36" (91.4 cm) min. cabinet width
B. 1" (2.5 cm) top of cutout to bottom of upper 
cabinet door
C. 32" (81.3 cm) bottom of cutout to floor
D. 34
¹⁄₂" (87.6 cm) cutout width
E. 1
¹⁄₂" (3.8 cm) min. bottom of cutout to top of 
cabinet door
F. 27
³⁄₄" (70.5 cm) min. cutout height
A. 23
¹⁄₄" (59.1 cm) min. cutout depth
B. 23" (58.4 cm) recessed oven depth
C. Oven front
D. Recessed oven
E. Cabinet
A
B
C
D
E
F
A
B
C
D
E
Single Oven
A. Model/serial number plate
A