Honeywell RTH8500 用户指南

下载
页码 60
33-00133EF—01
 22
System setup
Function 
Settings & Options
0170
Select System  
Type
If you are not sure of 
your heating/cooling 
system type or have 
other questions, 
go to  
wifithermostat.com
Heat/cool: Gas, oil or electric heating with central air conditioning.
Heat pump: Heat pump without backup or auxiliary heat.
Heat only with fan: Gas, oil or electric heat without central air 
conditioning.
Heat only (no fan): Gas, oil or hot water heat without central air 
conditioning.
Cool only: Central air conditioning only.
Heat pump: Heat pump with backup or auxiliary heating.
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2 
cooling stages (wires on 
Y and Y2).
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1 
cooling stage (wire on 
Y).
10 
Heat/Cool Multiple stages: 1 heat stage (wire on W), 2 cooling stages 
(wires on 
Y and Y2).
How do I set my heating/cooling system type? (See page 20 for instructions.)
Function 
Settings & Options
Note: 
Depending on system settings, functions on this page might not appear.
0180
Heating Fan 
Control
Gas or oil heat: Use this setting if you have a gas or oil heating system 
(system controls fan operation).
Electric heat: Use this setting if you have an electric heating system 
(thermostat controls fan operation).
0190
Heat Pump 
Changeover Valve 
(for heat pumps 
only)
Cooling changeover valve: Use this setting if you connected a wire 
labeled “O” to the O/B terminal.
Heating changeover valve: Use this setting if you connected a wire 
labeled “B” to the O/B terminal.
0240
Heating Cycle  
Rate
Gas or oil furnace: Standard gas/oil furnace (less than 90% efficiency).
Electric furnace: Electric heating systems.
Hot water or high-efficiency furnace: Hot water system or gas furnace 
(more than 90% efficiency).
Gas/oil steam or gravity system: Steam or gravity heat systems.
0250
Heating Cycle  
Rate Stage 2
How do I customize my heating/cooling system? (See page 20 for instructions.)
Function 
Settings & Options
0280
Backlight
Backlight off, then on for approximately 8 seconds after keypress.
Backlight always on low intensity, full bright after keypress.
0300
Manual/Auto 
Changeover
See page 20 for 
more information.
Manual changeover (Heat/Cool/Off).
Automatic changeover (Heat/Cool/Auto/Off). Automatically turns on Heat 
or Cool based on room temperature. Note: System maintains minimum 
3°F difference between heat and cool settings.
0320
Temperature 
Format (°F/°C)
Fahrenheit
Celsius
0330
Automatic Daylight 
Saving Time 
Adjustment
Off
On
What other functions can I change? (See page 20 for instructions.)