Step 4.3  Performing final check and trial 
operation
1. 
Check the following: 
•  Strength of the installation site 
•  Tightness of pipe connection to detect gas 
leak 
•  Electric wiring connection 
•  Heat-resistant insulation of the pipe 
•  Drainage 
•  Grounding conductor connection 
•  Correct operation (Take the following steps.) 
2. 
Press the   (Power) button on the remote 
control to check the following: 
•  The indicator on the indoor unit lights up. 
•  The airflow blade opens and the fan gears up 
for operation. 
3. 
Press the   (Mode) button to select Cool or Heat 
mode. Then take the following sub-steps: 
•  In Cool mode, use the Temperature button to 
set the set temperature to 16 °C. 
•  In Heat mode, use the Temperature button to 
set the set temperature to 30 °C. 
•  Check whether, approximately 3 to 5 minutes 
later, the outdoor unit starts, and a cool or 
warm air blows out. 
•  After 12 minutes of stationary condition, check 
the indoor unit air treatment. 
4. 
Press the   (Air swing) button to check whether 
the airflow blades work properly. 
5. 
Press the   (Power) button to stop the trial 
operation. 
Pumping down refrigerant
Pump-down is an operation intended to collect 
all the system refrigerant in the outdoor unit. This 
operation must be carried out before disconnecting the 
refrigerant tubing in order to avoid refrigerant loss to the 
atmosphere. 
1. 
Shut off the liquid valve with the Allen wrench. 
2. 
Turn on the air conditioner in cooling with fan 
operating at high velocity. (Compressor will 
immediately start, provided 3 minutes have 
elapsed since the last stop.) 
3. 
After 2 minutes of operation, shut the suction 
valve with the same wrench. 
4. 
Turn off the air conditioner and switch mains 
supply off. 
5. 
Disconnect tubing. After disconnection, protect 
valves and tubing ends from dust. 
  CAUTION
•  Compressor damage may occur if the compressor is 
run at a negative suction pressure.
Pumping down for removing the product
1. 
Turn on th air conditioner and select Fast Cool 
mode. 
2. 
Let the compressor run for more than 5 minutes. 
If the compressor does not operate for more than 
5 minutes due to protection control, wait about 2 
minutes, and then carry out the next procedure. 
3. 
Release the valve caps on High and Low pressure 
side. 
4. 
Use L-wrench to close the valve on the high 
pressure side. 
5. 
After approximately 1 minute, close the valve on 
the low pressure side. 
6. 
Stop operation of the air conditioner by pressing 
the   (Power) button on the indoor unit or 
remote control. 
7. 
Disconnect the pipes. 
1
2
Gas service port 
<Low pressure>
Liquid service port 
<High pressure> 
1 minute
Off