Installation requirements
Installation requirements
English
16 
Gas requirements
WARNING
•  Use only natural or LP (liquid propane) 
gases.
•  THE INSTALLATION MUST CONFORM 
WITH LOCAL CODES, OR IN THE 
ABSENCE OF LOCAL CODES, WITH 
THE NATIONAL FUEL GAS CODE ANSI/
Z223.1, LATEST REVISION (FOR THE 
UNITED STATES), OR WITH THE CAN /
CGA-B149 INSTALLATION CODES (FOR 
CANADA).
•  Gas dryers are equipped with a burner 
vent for use with natural gas. If you 
plan to use your dryer with LP (liquid 
propane) gas, it must be converted 
for safe and proper performance by a 
qualified service technician.
•  A 1/2” (1.27 cm) gas supply line is 
recommended and must be reduced to 
connect to the 3/8” (1 cm) gas line on 
your dryer. The National Fuel Gas Code 
requires that an accessible, approved 
manual gas shut-off valve be installed 
within 6” of your dryer.
•  Gas dryers installed in residential 
garages must be raised 18 inches (46 
cm) above the floor.
•  Additionally, a 1/8” (0.3 cm) N.P.T. 
(National Pipe Thread) plugged tapping, 
accessible for test gauge connection, 
must be installed immediately upstream 
of your dryer’s gas supply connection.
•  Your dryer must be disconnected from 
the gas supply pipe system during any 
pressure testing of the system.
•  Do not reuse old flexible metal gas 
lines. Flexible gas lines must be 
design certified by the American Gas 
Association (CGA in Canada).
NOTE
•  Your dryer uses an automatic ignition 
system to ignite the burner. There is no 
constant burning pilot.
•  Any pipe joint compound used must be 
resistant to the action of any liquefied 
petroleum gas.
•  As a courtesy, most local gas utilities 
will inspect a gas appliance installation.
Commonwealth of Massachusetts 
installation instructions
Your dryer must be installed by a licensed 
plumber or gas fitter. A “T” handle manual 
gas valve must be installed in the gas 
supply line to your dryer. If a flexible gas 
connector is used to install your dryer, the 
connector can be no longer than 3’ (36”).
WARNING
•  Gas leaks may occur in your system, 
creating a dangerous situation.
•  Gas leaks may not be detected by smell 
alone.
•  Gas suppliers recommend you purchase 
and install a UL-approved gas detector.
•  Install and use in accordance with the 
manufacturer’s instructions.